01-282
Rapid data transfer
Q
04 - Basic setting
Indicated on display:
- Confirm entry with key Q.
Basic setting HELP
Enter display group number XXX
Indicated on display:
- Press keys 0, 6 and 9
- Confirm entry with key Q.
ABS warning light flashes.
Basic setting 69 OFF <4-ON>
Compens. OK
0.3m/s2
Indicated on display:
Note:
After successfully completing the zero
compensation the values in display do not
go to 0.00 m/s2
Function is unknown or cannot be -
performed at moment
If this display appears the login procedure
has not been performed successfully.
- or:
Basic setting 69 OFF <4-ON>
Compens. n. poss.
5.0m/s2
If this appears on display, the measured
values are not within the accepted tolerance
for zero compensation.
- Check measured values with help of
function 08 "Read measured value block"
Page 01-240
, Display group number
006.
Стр
. 124
из
129
On Board Diagnostic (OBD), performing