01-299
Test table (test steps 1 - 16)
Test steps 17 - 23
see
Page 01-313
Note on test table
The socket designations of adapter V.A.G 1598/33 are identical to the ABS control module
(w/EDL) -J104- contact designations in wiring diagram.
Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
If the readings obtained deviate from the specifications, carry out repair measure in the
right-hand part of the table.
Electrical Wiring Diagrams, Troubleshooting & Component Locations binder
Continuity checks with adapter set V.A.G 1594 A (bridging).
If the measured figures only deviate slightly from the specifications, clean sockets and plugs
of the testers and adapter cables (with contact spray G 000 700 04 ) and repeat check.
Before replacing components, check wiring and connections and also, particularly for
specifications of less than 10
, repeat resistance check on the component.
Стр
. 12
из
38
Electrical check of Mark 60