01-93
Basic setting HELP
Enter display group number XXX
Indicated on display:
- Press keys 0, 0 and 1
- Confirm entry with key Q.
System in basic setting
1
Depress pedal and hold...
Indicated on display:
- Operate pedal with substantial foot
pressure and hold.
Pedal moves down
Hydraulic pump runs
Pedal comes back
System in basic setting
1
Rel. pedal; FR/FL bleed screw OPEN <3>
Indicated on display
- Press key 3 on V.A.G 1551 or arrow up
key on VAS 5051.
System in basic setting
2
Please wait...(10 secs.)
Indicated on display
Hydraulic pump runs
System in basic setting
2
Depr. pedal 10X; bleed screw CLOSED <3>
Indicated on display
- Press key 3 on V.A.G 1551 or arrow up
key on VAS 5051.
Стр
. 73
из
81
ABS ITT Mk 20 IE On Board Diagnostic (OBD) program