9. Simultaneously press and hold the sharpening and deburring stone
buttons for 3-4 seconds. Release the buttons.
NOTICE: NOTICE: Pressing the buttons for longer than 3-4 seconds
could bend the blade, which could then damage the
slicer.
10.Press and release the OFF (O) button and unplug the slicer.
11.Return the sharpener to the original position.
12.Clean the slicer. See “Clean and Sanitize the Slicer” on page 5.
Lubricate the Carriage Slide
Lubricate the carriage slide at least once a month and any time that
pushing the tray becomes difficult.
NOTICE: NOTICE: Use the oil supplied with the slicer or a food safe
lubricant. Do NOT use vegetable oil or oil containing
silicone. Do NOT spray oil onto the slicer components.
Sprayed oil could unintentionally reach areas of the slicer
that should not be lubricated.
1. Press and release the OFF (O) button.
2. Unplug the slicer from the electrical outlet.
3. Use a clean soft cloth to clean the carriage slide.
4. Pull carriage all the way forward. This will align the carriage slide
with the oil access hole (OIL) on the front of the slicer. If the slide is
not aligned, oil will drip and pool below the slicer.
5. Put a few drops of the oil that was supplied with slicer into the
carriage slide lubricant access hole.
TROUBLESHOOTING
SERVICE AND REPAIR
Serviceable parts are available on Vollrath.com.
To avoid serious injury or damage, never attempt to repair the unit or
replace a damaged power cord yourself. Do not send units directly to
The Vollrath Company LLC. Please contact Vollrath Technical Services
for instructions.
When contacting Vollrath Technical Services, please be ready with the
item number, model number (if applicable), serial number, and proof of
purchase showing the date the unit was purchased.
WARRANTY STATEMENT FOR THE VOLLRATH CO.
The Vollrath Company LLC warrants the products it manufactures or
distributes against defects in materials and workmanship as specifically
described in our full warranty statement.
For complete warranty information, product registration and new
product announcement, visit www.vollrath.com.
Problem
Might Be Caused By
Course of Action
Poor cutting performance.
The blade needs to be sharpened.
Sharpen the blade.
Poor cutting performance even though
blade is routinely sharpened.
Sharpening process is incorrect.
Repeat the sharpening process. Press and hold the sharpen-
ing stone button for a few seconds longer to allow burrs to
form on the blade. If the problem persists contact Vollrath
Technical Services.
No sparks when sharpening.
Sharpening stones need to be replaced.
Replace the stones.
Dirty sharpening stones.
Blade was not cleaned prior to sharpening. Replace the stones.
Overload reset is activating too often.
Contact Vollrath Technical Services.
Gauge plate is difficult to adjust
Gauge plate slide needs lubrication.
Lubricate the gauge plate slide with the oil supplied with the
slicer or with a food-grade lubricant.See page 6.