AUTOFILL UNIT
INSTALLATION INSTRUCTIONS
FLUSHING WATER THROUGH THE TUBING
The following procedure should be completed as state
and local codes dictate.
These steps can be completed when the machine is
operating with product in the tanks.
Repeat the following steps for each tank.
1. Press the Auger Movement button on the
machine to turn off the auger and deactivate the
AutoFill system.
2. Disconnect the syrup and water tubing from the
Speedfit elbows on the tank. Place the tubing in a
large bucket.
NOTE
The AutoFill tubing requires about 15 gallons of
water to be thoroughly cleaned. If using a 5-gallon
bucket, fill and empty it three times.
3. Turn
the
Dispense/Sanitize lever on the AutoFill
unit to the Sanitize setting. The arrow on the lever
should point down.
4. Press the Auger Movement button.
5. When the bucket is full, press the Auger
Movement button to stop the AutoFill system.
6. Turn
the
Dispense/Sanitize lever to the Dispense
setting. The arrow on the lever should point up.
7. Place the tubing in an empty bucket and press
the Auger Movement button. This will flush water
out of the pump and tubing. When pure syrup
comes out of the product tubing, press the Auger
Movement button and empty the bucket.
8. Connect the syrup and water tubing to the
Speedfit elbows at the tank.
9. Press the Auger Movement button to continue
normal operation.