35
15.3
Lead screw greasing
•
This operation have to be performed each 3-4 working days to ensure the tool working life.
•
Use the grease provided within this tool or in any case Lithium Soap grease NLGI class 2.
•
With the tool connected to the battery, open the blades by pressing the trigger(1), then switch off
the battery and remove the cable (2):
•
Remover the trigger protection by unscrewing the fixing screw (3), disengage the protection from
the rear side first (4) and from the front side then (5):
•
Check and remove any cutting residual from the zone below the trigger protection. Unscrew the
greasing screw from the actuation rod (6 ) and apply the grease inside the hole (7):
•
Repeat the inverse procedure to reassemble.
15.4
Moving blade replacement
•
Use only original blades, refer to customer assistance service to buy blades and original spare
parts.
•
With the tool connected to the battery, open the blades by pressing the trigger(1), then switch off
the battery and remove the cable (2):
Summary of Contents for KV500
Page 124: ...124 ...