Remover the trigger protection by unscrewing the fixing screw (3), disengage the protection from
the rear side first (4) and from the front side then (5):
•
Remove the circlip (6) and the pin (7) from the moving blade actuator rod:
•
Remove the blade fixing screw (8) and locking device (9), unscrew the nut (10) and remove the
blade pin(11):
•
The moving blade can be replaced now (12). Add grease to the fix blade in the indicated
position(13):
•
Repeat the inverse procedure to reassemble the tool. During the reassemble operation add grease
to the blade pins.
•
Between operation 8 and 7, move the blade by hand to evaluate the smooth relative movement
between the blades. If the movement is difficult the locking nut has to be released by one step. If
there is lateral freeplay the locking nut has to be tightened of one step.