Davide e Luigi Volpi S.p.A.
Via San Rocco,10 – 46040 Casalromano (MN) – Italy
Tel. +39 0376.76009 - 76012 Fax. +39 0376.76408
E-mail: commerciale@volpioriginale.it – export@volpioriginale.it
DAVIDE E LUIGI VOLPI S.p.A. - Via San Rocco,10 - 46040 CASALROMANO (MN) - ITALY YLB19VBE_2 Libretto d’uso V_BLACK ELEKTRON pag. 16 di 48
5.7.
CHANGE OF LIQUID IN THE TANK
In case a change of the liquid inside the tank is necessary, follow the instructions given in point 5.6 and after that, the
instructions in point 5.2.
6.
MAINTENANCE
6.1.
INTRODUCTION
A correct use of the sprayer and a regular maintenance are necessary to keep the sprayer in the best working, efficacy and
safety conditions.
Use exclusively original spare-parts.
6.2.
BATTERY RECHARGE
The sprayer powered by a sealed storage battery, rechargeable with the supplied battery charger R (Fig. A).
A 5-Ampere fuse E, placed on the side of the machine base, protects the electric motor from eventual overloads and the battery
from eventual short-circuits.
In order to handle the battery in a safe way it is necessary to follow the below listed instructions:
•
Keep the battery away from high temperatures (ex. flames).
•
Do not open the battery.
WARNING
: During the recharge operations, follow safe working procedures and carefully observe the general safety rules.
In order to recharge the battery, follow these instructions:
•
Turn off the general switch (Fig. “A”)
•
Check that the network voltage corresponds to the indication printed on the battery charger plate R (Fig. “A”).
•
Connect the battery charger R (Fig. “A”) to a suitable and electrically protected current-socket.
•
Insert the battery-charge plug R (Fig. “A”) in its specific socket D (Fig. “A”) placed on the side of the sprayer base.
•
To recharge the battery completely, you need 6-7 hours.
•
At the end of the re-charge it is recommended to disconnect the battery charger from the power network first and then
from the sprayer;
•
During long periods of inactivity, check that the general switch A (Fig. “A”) is off.
The battery life mostly depends on the observance of some important rules:
•
Do not create a short-circuit.
•
Do not discharge it excessively: when the battery is almost discharged, charge it immediately.
•
Promptly recharge it with the general on/off switch turned off and respecting the necessary time of charging.
•
For the recharge exclusively use the battery charger supplied with the sprayer.
•
Do not turn the sprayer on when the battery charger is connected.
•
After the complete recharge keep the battery between 5 and 40° C.
•
In case of long stocking or non-use,
recharge the battery every four months.
When the battery is no longer rechargeable it is necessary to replace it with another one with the same sizes and features,
respecting the connection polarities; the old battery shall be taken to an authorized collecting point.
7.
PROBLEMS – CAUSES – SOLUTIONS
PROBLEMS
POSSIBLE
CAUSES
SOLUTIONS
When activating the handle
lever, no water is coming out
Motor does not work
General switch off
Turn on general switch
Pressure regulator off
Switch on the regulator
Exhausted battery
Replace or recharge
Blocked pump
Contact the service centre
Broken cable
Contact the service centre
Engine failure
Contact the service centre
Blown fuse
Replace the fuse
Motor works
Clogged nozzle
Clean
Clogged tank filter
Clean
Clogged handle filter
Clean
Defective pump
Contact the service centre
Little water comes out when
pressing the handle lever
Pressure regulator at minimum
Raise the regulator
Dirty nozzle filter
Clean
Dirty handle filter
Clean
Defective pump
Contact the service centre
Dirty nozzle
Clean