Install Fixture

3

Wire Connections

4

VOLT

®

 Floodlight with Motion Sensor

VFL-40XX-MS-ABZ

Fixture

Yoke Mount

Bolt

Hex Nut

Washer

Wall

Remove the hex nuts and the 

washers from the wall anchors. 

Attach the yoke mount of the 

fixture to the wall anchors and 

secure them in place with the 

previously removed washers and 

hex nuts. Tighten until snug.

Adjust Fixture and IR Sensor

5

Wall

Fixture

Set Screw

IR Sensor

Wrench

Adjust the fixture to your desired

orientation and tighten set screws

with a wrench.

Adjust the IR sensor to proper 

orientation.

After installation, but before power is on:

A. Check whether the lighting fixture is firmly fixed. 
B.  Check whether wires are connected properly.

Infrared (IR) Sensor

max.

11.48 Ft.

min.

6.56 Ft.

This product can be installed outdoors. It is recommended to install in 

these orientations to protect the flood light against heavy rain.

INSTALLATION INSTRUCTIONS

Fixture

Strip both leads from the fixture pigtail and main supply cable. 

Using two wire connectors (sold separately), connect the leads from 

the fixture to the main supply cable leads.

Wire Connectors

Pigtails

Main Supply 

Cable

Supply Cable 

from Fixture

Summary of Contents for VFL-40 MS-ABZ Series

Page 1: ... MS ABZ INSTALLATION INSTRUCTIONS Specifications and product details subject to change without notice Copyright 2019 VOLT Lighting Lutz FL USA 33549 All rights reserved customersupport voltlighting com 813 978 3700 Help Hotline 1 813 978 3700 Mon Fri 8am 8pm Sat Sun 10am 6pm EST 1 ...

Page 2: ...atts 25 AMPS at 12 volts 4 Underground Low Energy Cable must not be buried over 6 15 2 cm in order to connect to the main low voltage cable 5 Wiring connections must be made with wire connectors that is suitable for outdoor use 6 Position the wire connector so that it is located within 6 inches 15 2 cm from a building structure a luminaire or fitting INSTRUCTIONS PERTAINING TO A RISK OF FIRE OR IN...

Page 3: ...mounting surface Place a mark on the wall using the holes of the mount These marks will be used for the wall anchors Wall Anchors Hole Wall Drill the holes for the wall anchors using the marks on the wall Insert the wall anchors into the drilled holes Tighten the hex nuts on the bolts until they are secure to the wall INSTALLATION INSTRUCTIONS 10W Flood Light 30W Flood Light 8 25 4 25 7 35 8 85 8 ...

Page 4: ...fixture to your desired orientation and tighten set screws with a wrench Adjust the IR sensor to proper orientation After installation but before power is on A Check whether the lighting fixture is firmly fixed B Check whether wires are connected properly Infrared IR Sensor max 11 48 Ft min 6 56 Ft This product can be installed outdoors It is recommended to install in these orientations to protect...

Page 5: ...nated 15 minutes after the sensor is triggered b At the minimum setting the fixtured is illuminated 7 seconds after the sensor is triggered 3 SENS If the sensor is too sensitive or not sensitive enough it can be adjusted here Replace IR Sensor 1 Remove Backing with IR Sensor Rotate the bracket so that the backing can easily be removed from the fixture Remove the backing with IR sensor from the fix...

Page 6: ...ectors with pliers to engage crimp connectors Back Fixture IR Sensor Supply Cable Connector Wires Brown Wire from Sensor Black Wire from Supply Cable Connector Red Wire from Sensor Blue Wire from Sensor Red Wire from Luminaire Black Wire from Luminaire White Wire from Supply Cable 4 Make Connections of IR Sensor Wires Carefully tuck all the wires inside of the back housing Place the backing with t...

Page 7: ... without notice Copyright 2019 VOLT Lighting Lutz FL USA 33549 All rights reserved customersupport voltlighting com 813 978 3700 w w w v o l t l i g h t i n g c o m IS VFL 40XX MS ABZ ver1 pdf Help Hotline 1 813 978 3700 Mon Fri 8am 8pm Sat Sun 10am 6pm EST ...

Reviews: