background image

5

CLEANING THE EXHAUST FILTER
30

  

Open the filter grill.

31

  

Remove the exhaust filter.

32

  

Rinse it under tap water and dry it completely.

31

  

Put the filter back into the cleaner.

30

  

Close the filter grill.

Exhaust filter reference number: Menalux F110

TROUBLE FINDING YOUR MENALUX FILTERS?

If you do not find Menalux at yours tore , please call Volta 

customer service on 1300 365 305 (Aus), 0508 730 730 (NZ).

OPERATING THE HOSE IN/OUT OF THE SUCTION INLET
33 

 

To connect the hose into the suction inlet push it until 
it clicks. To disconnect the hose from the suction inlet 
push the button at the end of the hose.

WARNING:

 On collection of proprietary carpet conditioning 

powders, plaster/concrete dust, it is recommended that the 
dust container is emptied and the cartridge filter is cleaned 
after every use. Some of the preparations contain substances 
which while left in the vacuum cleaner for extended periods 
could create damage.
Many air fresheners, household deodorants, sprays and 
polishes contain highly inflammable gas propellants. Because 
of this it is particularly important that these products are 
used strictly in accordance with the relevant manufacturers 
instructions. It is essential that none of the above products  
are sprayed directly into the vacuum cleaner.

TROUBLE SHOOTING AND CUSTOMER INFORMATION

The vacuum cleaner does not start.

1.

  

Check whether the dust container is full, if so empty 
and clean the cartridge filter if showing build up of 
dust residue, also inspect the exhaust filter, If severely 
discoloured it is to be replaced.

2.

 

Check that the plug and the cable are not damaged.

3.

 

Check for a blown fuse.

The vacuum cleaner stops when in use.

1.

 

Check whether the dust container is full, if so  empty 
and clean the cartridge filter if showing build up of 
dust residue, also inspect the exhaust filter. If severely 
discoloured it is to be replaced.

2.

 

Is the nozzle, tube or hose blocked?

3.

 

Are the filters blocked?

Blockages and dirty filters can result in the cleaner switching 
off in operation, due to restriction of air flow causing the 
activation of the thermal overload. If this does occur switch 

off the cleaner at the mains and remove the plug. Allow the 
cleaner to cool for 20 - 30 minutes. In this time check the hose, 

tubes and nozzle for blockages.
(a) To check for a hose blockage pass a small coin through 
it, on finding the blockage remove it by pressing the hose to 
dislodge and loosen the obstruction. However be careful in 
the case it has been caused by glass or needles caught inside 
the hose at the point of the blockage.
(b) By passing a flexible tube through the hose from the 
handle end the blockage can also be removed.

If the obstruction can not be removed please consult the 
Service Providers listing supplied with the cleaner for your 

closest Volta Authorised service provider. The clearing of 

 

a blocked hose is not covered by warranty.
Water has entered the vacuum cleaner.
It will be necessary to replace the motor by an authorised 
Volta service agent. Damage to the motor caused by the 
penetration of water is not covered by the warranty.

CUSTOMER INFORMATION

Should you require service or consumable spares for your 
Volta cleaner, please consult the service providers listing 
enclosed with this cleaner for your nearest Electrolux 
authorised service provider or contact the Customer  

service help line on 1300 365 305 (Aus), 0508 730 730 (NZ).

PROTECTING THE ENVIRONMENT

• 

Attempt to recycle packaging material and 

 

old appliances.

• 

The cardboard packaging can be placed in the 

 

waste paper collection.

•  

Deposit the plastic bag made of polyethylene (PE) 

 

at the PE collection point for recycling.

•  

Deposit the polystyrene foam at the PS collection 

 

point for recycling.

RECYCLING THE APPLIANCE AT THE END OF ITS LIFE:

•  

The plastic components all carry a material 

identification marking so that, like the other materials, 
they can recycled at the end of the life of the appliance.

•  

Please inquire with your local authority.

BLOCKED AIR FLOW AND DIRTY FILTERS

•  

The cleaner stops automatically if a blockage occurs 

 

in the nozzle/tube/hose or if the filters are blocked 
with dirt.

•  

Disconnect from mains and allow the cleaner to 

 

cool for 20-30 minutes. Remove blockage and/or 

 

clean filters.

•  

Restart the cleaner.

The symbol 

 on the product or on its packaging indicates 

that this product may not be treated as household waste. 
Instead it shall be handed over to the applicable collection 
point for the recycling of electrical and electronic equipment. 
By ensuring this product is disposed of correctly, you will help 
prevent potential negative consequences for the environment 
and human health, which could otherwise be caused by 

inappropriate waste handling of this product. For more 

detailed information about recycling of this product, please 
contact your local city office, your household waste disposal 
service or the shop where you purchased the product

MAINTENANCE AND CUSTOMER INFORMATION

35117_U1661 Lite_IFU_V4.indd   5

8/10/08   9:43:31 AM

Summary of Contents for Volta Lite U1660

Page 1: ...1 Volta Lite U1660 Instruction Manual 35117_U1661 Lite_IFU_V4 indd 1 8 10 08 9 43 20 AM ...

Page 2: ...uum cleaner with wet hands 10 Do not put any object into openings Do not use with any opening blocked Keep free of dust lint hair and anything that may reduce airflow 11 Keep hair loose clothing fingers and all parts of body away from openings and moving parts 12 Turn all controls off before unplugging 13 Use extra care when cleaning on stairs 14 Do not use to pick up flammable or combustible liqu...

Page 3: ...h 4 Cable rewind button 5 Wheel 6 Dust container 7 Dust container handle 8 Dust container open button 9 Carrying handle 10 Hose 11 Telescopic tube 12 Combination floor nozzle 13 Floor nozzle 14 Crevice nozzle 15 Upholstery nozzle 16 Cartridge filter 17 Protector mesh 18 Vertical parking 19 Horizontal parking 35117_U1661 Lite_IFU_V4 indd 2 8 10 08 9 43 25 AM ...

Page 4: ...icator is still active it means that the cartridge filter is clogged In this case follow the instructions of chapter Replacing or cleaning the cartridge filter 22 Remove the dust container by pushing the open buttons on the two sides of the dust container handle 23 Remove the contents of the dust container by pushing the orange coloured opening button 24 25 If necessary the protector mesh also can...

Page 5: ...4 30 22 23 24 25 26 27 28 29 A B C 31 32 33 35117_U1661 Lite_IFU_V4 indd 4 8 10 08 9 43 31 AM ...

Page 6: ...he hose to dislodge and loosen the obstruction However be careful in the case it has been caused by glass or needles caught inside the hose at the point of the blockage b By passing a flexible tube through the hose from the handle end the blockage can also be removed If the obstruction can not be removed please consult the Service Providers listing supplied with the cleaner for your closest Volta ...

Page 7: ...ective parts or workmanship Electrolux is not liable in the following situations which are not exhaustive A The Appliance is damaged by i use with anything other than Volta genuine spare parts ii accident iii vacuuming up wet materials or construction building materials that is not normal day to day domestic dry use iv misuse neglect or abuse including failure to properly maintain or service v nor...

Page 8: ...d Ph 09 273 8340 www electrolux co nz Some models may be limited in availability or be available from certain stores only Not all models and specifications are available at time of printing and not all models are available in NZ See your local Volta retailer or call the above phone numbers for further information if required Due to the Electrolux policy of continual product development specificati...

Reviews: