background image

 oPERATING INSTRUCTIoNS

Version 04/09

Temperature and Humidity Datalogger

Item No. 10 00 55

INTENDED USE

1. 

This  temperature  and  humidity  datalogger  is  intended  to  be  used  for  monitoring  and  collecting  data  of 
environment  temperature  and  humidity.  It  is  used  to  monitor  and  collect  temperature  and  humidity  values 
efficiently and conveniently for long time periods. The readings are saved in the logger and simply read out 
by PC with a USB port. The LCD can show current readings, MAX, MIN, TIME, DATE and temperature or 
humidity values. The datalogger is designed with a high accuracy temperature and humidity sensor with fast 
response and stability.

Unauthorised conversion and/or modification of the device are inadmissible because of safety and approval 
reasons (CE). Any usage other than described above is not permitted and can damage the product and lead to 
associated risks such as short-circuit, fire, electric shock, etc. Please read the operating instructions thoroughly 
and keep them for further reference.

SAFETY INSTRUCTIoNS

2. 

We  do  not  assume  liability  for  resulting  damages  to  property  or  personal  injury  if  the 
product has been abused in any way or damaged by improper use or failure to observe 
these operating instructions. The warranty/ guarantee will then expire!
The  icon  with  exclamation  mark  indicates  important  information  in  the  operating 
instructions. Carefully read the whole operating instructions before operating the device, 
otherwise there is risk of danger.

Personal safety

The product is not a toy and should be kept out of reach of children!

• 

Product safety

When used in conjunction with other devices, observe the operating instructions and safety 

• 

notices of  connected devices.
The product must not be subjected to heavy mechanical stress.

• 

The product must not be exposed it to extreme temperatures, direct sunlight, intense vibration, 

• 

or dampness.

Battery safety

Correct polarity must be observed while inserting the batteries.

• 

Batteries  should  be  removed  from  the  device  if  it  is  not  used  for  a  long  period  of  time  to 

• 

avoid damage through leaking. Leaking or damaged batteries might cause acid burns when in 
contact with skin, therefore use suitable protective gloves to handle corrupted batteries.
Batteries must be kept out of reach of children. Do not leave the battery lying around, as there 

• 

is risk, that children or pets swallow it.
Batteries  must  not  be  dismantled,  short-circuited  or  thrown  into  fire.  Never  recharge  non-

• 

rechargeable batteries. There is a risk of explosion!

Miscellaneous

Repair works must only be carried out by a specialist/ specialist workshop.

• 

If  you  have  queries  about  handling  the  device,  that  are  not  answered  in  this  operating 

• 

instruction,  our  technical  support  is  available  under  the  following  address  and  telephone 
number:
Voltcraft

®

, 92242 Hirschau, Lindenweg 15, Germany, phone 0180 / 586 582 723 8

INSTALLATIoN AND GENERAL INFoRMATIoN

3. 

This Datalogger should be placed uprightly. If placed in low temperature and high humidity environment, 

• 

after measurement, the Datalogger should be placed uprightly until vaporizing the beads completely before 
reading the data in the device.
If the Datalogger is connected to the PC, some battery power can be saved.

• 

LCD ELEMENTS

4. 

This battery sign 

1. 

 will be displayed if battery is fully charged.  When battery is exhausted,  

 sign 

will be displayed. At that time, replacing a new battery is necessary.
TIME: When this icon is displayed then the values on the right hand side show the current time.

2. 

DATE: When this icon is displayed then the values on the right hand side show the current date.

3. 

Time and date display is switching automatically every 10 seconds.

REC: If this icon is shown then the data logger is under recording mode.

4. 

FULL: If this icon is shown then the storage memory is full. The data logger will stop recording.

5. 

%RH: If this icon is shown then the data logger is measuring the environment humidity.

6. 

°C: Temperatue shown in Centigrade

7. 

°F: Temperature shown in Fahrenheit

8. 

When uploading data to a PC, there will be the icon “-PC-“ displayed on the LCD. After all data is loaded, the 

9. 

data logger will display the real value from the current measurement. But it will stop recording. The logger 
needs to be re-set if you need the recording function again. You can only look over the data from the logger 
itself. All settings will be only carried through the software installed in PC. 

Alarm function 

10. 

When the measured value exceeds the set upper limit or lower limit, the alarm LED will light up one time 
per minute. A red LED shows that the temperature value exceeds the limit, while a yellow LED shows that 
the humidity value exceeds the limit. 

There will be the icon “-LO-” displayed if the temperature/humidity sensor is not well connected. At this time, 

11. 

please open the back cover and re-install the sensor. Until the correct measurement value is displayed.

oPERATIoN

5. 

Before operation, please install the software CD as some functions are only available using the 
software program.

Temperature/humidity mode

Press the button “Temp. / %RH” to switch between temperature and humidity display mode.

• 

It will be shown in the lower part of the LCD in a sequence: Temperature (ºF) –> Temperature (ºC) –> 

• 

Humidity.

Display MAX/MIN values

Press the button “MAX/MIN” to hold the maximum/minimum measurement and show the recorded values.

• 

It will be shown in the lower part of the LCD in a sequence: Maximum value -> Minimum value -> Off

• 

Time  and  date  display  of  the  maximum/minimum  values  is  switching  automatically  every  10 
seconds. If you do not press the button for 40 seconds, the meter will automatically exit from 
MAX/MIN mode and return to the the data hold and measure mode.

DISPoSAL

6. 

Dispose of waste electrical and electronic equipment

In order to preserve, protect and improve the quality of environment, protect human health and 
utilise natural resources prudently and rationally, the user should return unserviceable product to 
relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately and not as 
municipal waste.

Used batteries/ rechargeable batteries disposal

The user is legally obliged 

(battery regulation)

 to return used batteries and rechargeable batteries. 

Disposing  used  batteries  in  the  household  waste  is  prohibited!

  Batteries/  rechargeable 

batteries containing hazardous substances are marked with the crossed-out wheeled bin. The 
symbol  indicates  that  the  product  is  forbidden  to  be  disposed  via  the  domestic  refuse.  The 
chemical symbols for the respective hazardous substances are 

Cd

 = Cadmium, 

Hg

 = Mercury, 

Pb

 = Lead.

You can return used batteries/ rechargeable batteries free of charge to any collecting point of your 
local authority, our stores or where batteries/ rechargeable batteries are sold.

Consequently you comply with your legal obligations and contribute to environmental protection!

TECHNICAL DATA

7. 

Power consumption:

1 x 3.6V Lithium battery

Relative humidity accuracy: 

±

5% (for 0% to 20%)

±

3.5% (for 20% to 40% / for 60% to 80%)

±

3% (for 40% to 60%)

Temperature accuracy:

±

2

°

C (for -40

°

C to -10

°

C / for +40

°

C to +70

°

C)

±

1

°

C (for -10

°

C to 40

°

C)

Resolution:

0.1% (relative humidity) / 0.1

°

C (temperature)

Memory:

32700

Measuring rate:

1 second to 24 hours

System requirement (for software): Microsoft Windows® 2000 / XP / Vista™
Dimensions ( L x W x H):

94 x 48 x 33 mm

Weight:

115 g

These operating instructions are published by Voltcraft

®

Lindenweg 15, D-92242 Hirschau/ Germany, Phone +49 180 586 582 723 8.
The operating instructions reflect the current technical specifications at time of print. 
We reserve the right to change the technical or physical specifications.

© Copyright 2009 by Voltcraft

®

.

*02_04/09_03-HW

Reviews: