36
10. LED DISPLay
LED
Description
Measure
No LED flashes:
The recording has not been
started yet.
The recording has stopped.
Start recording.
The battery is flat.
Insert a new battery.
The green LED flashes 1x: The record-
ing is running (the flashing interval can
be set in the PC software).
Push the button ”START/
STOP” (3) for approx. 3 s to
start/stop the recording.
The green LED flashes 2x :The memory
is full (flashing interval 20 s).
The data can be downloaded
onto the computer:
The green LED flashes 2x within 5 s:
The meter waits for start of recording
after configuration.
Push the button ”START/
STOP” (3) until the green
LED starts to flash.
The green LED flashes 6x within 3 s:
The device switches on.
The red LED flashes 1x: The wood
moisture low alarm set in the software
has been undercut (the flashing interval
corresponds to the scan rate).
The red LED flashes 2x: The wood
moisture high alarm set in the software
has been exceeded (the flashing interval
corresponds to the scan rate).
The green and red LEDs flash 1x at the
same time: The battery voltage is less
than 2.9v (The flashing interval is 18 s)
Replace the battery.
The green and red LEDs flash at the
same time: The recording has stopped.
You can download the
recorded data onto the
computer.
Green > Red >
Green
The recording is started.