background image

Locking the cable lock
Push the cable (C) into the corresponding opening of the cable lock until it clicks into place.

   This is only possible if the numeric code is set correctly.

Twist the 3 dials (A) so that instead of the combination for unlocking the cable lock (the default 

factory setting is “000”) a different numeric code is shown. 
Resetting the numeric code
Set the dials to the current numeric code combination (see above “Unlocking the cable lock”).
With the help of a pin, push the adjusting knob at the bottom side of the cable lock all the way 

in (D) and hold the knob in this position.
Set a new 3-digit numeric code (on the side with the engraved line marking), for example “333”.
Release the adjusting knob. The numeric code is now changed.

Description of Symbols

1

2 3

4

5

6

7

8

7

8

8

7

9

10

A

B

C

D

  

1.  

The following battery symbol is displayed, when the battery is full: 

. (the battery 

voltage exceeds 3.4 V)

  If the battery is almost exhausted, the following symbol is displayed: 

.

  (The battery voltage is below 3.0 V.) At that time, a new battery must be inserted.)
2.  “TIME”   If this symbol is displayed, figures on the right indicate the current time.
3.  “DATE”   If this symbol is displayed, figures on the right indicate the current date. Time and 

date indications are updated automatically every 10 seconds.

4.  “REC”   If this symbol is displayed, the data logger is in the recording mode. 
5.  “FULL”   If this symbol is displayed, the memory is full. The data logger stops recording.
6.  “%RH”   If this symbol is displayed, the data logger is measuring the ambient air humidity.
7.  “°C” 

The temperature is displayed in degrees Celsius. 

8.  “°F” 

The temperature is displayed in degrees Fahrenheit. 

9.  “MAX”   If this symbol is displayed, the displayed value constitutes the maximum value of 

the data set.

10. “MIN”   If this symbol is displayed, the displayed value constitutes the minimum value of 

the data set.

A  Time or date is displayed.
B  Ambient temperature or air humidity is displayed.
C  Temperature display of the probe input TK2. 
D  Temperature display of the probe input TK1. 

Software installation

•  Place the CD in the CD-ROM drive of your computer.
•  The installation starts automatically. If not, open your CD ROM directory and then the instal-

lation file “autorun.exe”.

•  Select the desired language (German, English or French).
•  Follow the instructions in the dialogue window, select the target folder for the installation and 

carry out the installation.

•  For more information please take note of the operating instructions contained on the CD.
•  The software enclosed is the Voltsoft Standard Edition. The Professional Version (Voltsoft 

Data Logger, No. 101333) may be purchased separately. When you purchase the profes-

sional version, you will get the corresponding licence key.

•  Follow the instructions in the Voltsoft operating manual in order to perform an upgrade from 

your software to the professional version and to register the software.

•  The current version may be downloaded at www.conrad.de by entering the order number in 

the downloads tab.

Features overview:

Standard

Professional

User management

Email management

General settings

Language preference

Mail template

Device management (addition / deletion)

User-defined charts

Email notification

Web interface

Operation

   Please install the software from CD before operation. Some functions are only avail-

able if the software is used.

a)  Temperature/air humidity mode 

Press the button “Temp / %RH” to switch between modes of ambient temperature and air 

humidity display.
The modes are indicated successively in the right zone of the LC-display. 
Temperature (ºC) → Air humidity.
Temperature display in ºF (Fahrenheit) can be selected using the software.
Refer to the software manual.

b)  Display of MAX/MIN values

Press  the  button  “MAX/MIN”  to  switch  between  maximum/minimum/current  measurement  

and recorded value indication.
The modes are indicated successively in the left upper zone of the LC-display.
Maximum value → Minimum value → Current measurement

c)  Alarm function 

The alarm LED starts flashing if the measured value exceeds the preset upper limit or falls 

below the preset lower limit. Double flashes of the red LED indicate that the temperature ex-

ceeded the upper limit, whereas normal flashes of the red LED indicate that the temperature 

fell below the lower limit. 
Flashing of the yellow LED shows that the preset air humidity value is exceeded.

Maintenance and Cleaning

Apart from the occasional battery change, the product is maintenance-free for you.
Never clean the product while it is connected to the computer. Use a clean, dry, soft cloth for 

cleaning. Do not use aggressive cleaning agents, as these can cause discolouration. To pre-

vent scratch marks, do not press too strongly on the surface when cleaning.

Summary of Contents for 1321033

Page 1: ...t der eingepr gten Strichmarkierung Bei Lieferung ist der Zahlencode 000 voreingestellt Zum Entriegeln dr cken Sie den seitlichen Knopf ein B und ziehen Sie das Kabel C heraus Bedienungsanleitung DL 1...

Page 2: ...lgen Sie den Anweisungen im Dialogfenster w hlen Sie das Zielverzeichnis f r die Instal lation aus und f hren Sie die Installation durch Beachten Sie f r n here Informationen bitte die auf der CD enth...

Page 3: ...bis 100 rF Messtoleranz Luftfeuchte 5 0 bis 20 und 80 bis 100 rF 3 5 20 bis 40 und 60 bis 80 rF 3 0 40 bis 60 rF b Umgebungstemperatur Messbereich 40 C bis 70 C 40 F bis 158 F Messtoleranz 2 C 40 C bi...

Page 4: ...ans of the 3 dials A on the side with the engraved line marking The numeric code default is 000 at delivery To unlock push the side button B in and pull out the cable C Operating instructions DL 141TH...

Page 5: ...rman English or French Follow the instructions in the dialogue window select the target folder for the installation and carry out the installation For more information please take note of the operatin...

Page 6: ...asurement range 0 rF to 100 rF Air humidity measurement tolerance 5 0 to 20 and 80 to 100 rF 3 5 20 to 40 and 60 to 80 rF 3 0 40 to 60 rF b Ambient temperature Measurement range 40 C to 70 C 40 F to 1...

Page 7: ...A avec une marque incrust e sur le c t Lors de la livraison le code chiffres est pr r gl sur 000 Lors du d verrouillage appuyez sur le bouton situ sur le c t et tirez sur le c ble Mode d emploi Enreg...

Page 8: ...ou Fran ais Suivez les instructions de la bo te de dialogue s lectionnez le r pertoire cible pour l installation et effectuez l installation Pour plus d informations veuillez vous r f rer au mode d em...

Page 9: ...humidit relative de l air Tol rance de mesure humidit de l air 5 0 20 et 80 100 d humidit relative de l air 3 5 20 40 et 60 80 d humidit relative de l air 3 0 40 60 d humidit relative de l air b Temp...

Page 10: ...j levering is de getalcode 000 in gesteld Om te ontgrendelen op de knop aan de zijkant B drukken en de kabel C eruit trekken Gebruiksaanwijzing DL 141TH2K Datalogger Bestelnr 1321033 Beoogd gebruik De...

Page 11: ...Kies de door u gewenste taal Duits Engels of Frans Volg de aanwijzingen in het dialoogvenster kies de doelmap voor de installatie en voer de installatie door Neem voor nadere informatie de gebruiksaa...

Page 12: ...ik 0 rF tot 100 rF Meettolerantie luchtvochtigheid 5 0 tot 20 en 80 tot 100 rF 3 5 20 tot 40 en 60 tot 80 rF 3 0 40 tot 60 rF b Omgevingstemperatuur Meetbereik 40 C tot 70 C 40 F tot 158 F Meettoleran...

Reviews: