55
d) AC current (A~)
Range
Accuracy
Resolution
600 µA
±(1.6 % r5 digits)
0.1 µA
6000 µA
1 µA
60 mA
±(2.0 % r8 digits)
0.01 mA
600 mA
0.1 mA
6 A
±(2.6 % r4 digits)
0.001 A
10 A
0.01 A
Overload protection: 600 µA to 600 mA range 600 mA; 6 A to 10 A range 10 A
LC display (4): true rms
Frequency response: 45 – 400 Hz
Accuracy guarantee range: 5 to 100 % of the range, shorted circuit allows least significant digit ≤2
If input current ≥10.10 A, acoustic alarm sounds; if input current>11 A “OL” symbol appears
Crest factor can reach up to 3.0 at max. range
Non-sinusoidal waveform: Crest factor=1.0 to 2.0 additional accuracy: 3.0 %
Non-sinusoidal waveform: 2.0 to 2.5 additional accuracy: 5.0 %
Non-sinusoidal waveform: 2.5 to 3.0 additional accuracy: 7.0 %
e) Resistance
Range
Accuracy
Resolution
600 Ω
±(1.6 % r3 digits)
0.1 Ω
6000 Ω
±(1.3 % r3 digits)
0.001 kΩ
60 kΩ
0.01 kΩ
600 kΩ
0.1 kΩ
6 MΩ
±(1.5 % r10 digits)
0.0001 MΩ
60 MΩ
±(2 % r8 digits)
0.01 MΩ
Measurement result = reading of resistor – reading of shorted test leads. Open circuit voltage 1 V
f) Capacitance
Range
Accuracy
Resolution
60 nF
±(4 % r10 digits)
0.001 nF
600 nF
±(4 % r3 digits)
0.01 nF
6 μF
1 nF
60 μF
10 nF
600 μF
±(5 % r9 digits)
100 nF
6 mF
1 μF
60 mF
±(10 % reading)
10 μF
Overload protection: 600 V / DC ; Overload protection: 600 V / AC
If the D value of capacitance >0.1, then the accuracy should multiplied by 2.