48
e) Maximum / Minimum
This function permits saving and display of maximum or minimum values during a series of measurements. Auto-
range will be deactivated.
• This mode is only applicable with the following functions:
LOZV , LPFV , V , V , mV
, Ω, µA
, mA , A
, and
°C/°F
.
• Select the proper range before selecting MAX MIN to ensure that the MAX MIN reading will not exceed the
measurement range.
• The values are taken from the time MAX MIN mode was entered. Input changes of 100 milliseconds or longer will
be recorded.
• Long press the
MAX MIN
button to enter/exit maximum and minimum measurement mode.
• Short press the
MAX MIN
button to cycle through measurements:
- Maximum value:
MAX
will show on the display.
- Minimum value:
MIN
will show on the display.
f) Automatic power off
Automatic power off is an energy saving feature. When activated, the power will turn off if there is no activity is
detected for approximately 15 mins. Press any button or adjust the function dial to wake.
1
Disable auto-power off
1. Set the function dial to the
OFF
position.
2. While pressing and holding the
SEL
/
PEAK
button, turn the function dial to any position.
3. The
symbol will disappear.
2
Activate auto-power off
• Restart the device by setting the function dial
OFF
then
ON
again.
• The
symbol will show.
g) Automatic backlight
When ambient light levels fall below a certain threshold, the backlight automatically turns ON (duration: 30 secs). In
bright circumstances, the backlight automatically turns OFF.