17. Technical data
a) General
Intended use ...................................Indoors
Voltage supply ................................9 V block battery (6F22, NEDA 1604 or same)
Operating time/battery ....................approx. 35 h (backlight always on, torch off, buzzer off)
Measuring impedance ....................approx. 10 MΩ (600 mV: ≥100 MΩ)
Display range ..................................4000 counts (characters)
Refresh rate ....................................2-3x per sec
Measuring method AC ....................True RMS
Measuring line length .....................each approx. 90 cm
Low battery indicator ......................≤6 V ±0.2 V
Measuring jacks distance ...............19 mm (COM-V)
Auto power off ................................approx. 15 minutes
Data hold ........................................approx. 15 minutes
Measuring category ........................≤ CAT III 600 V
Degree of contamination ................2
Direct voltage ..................................max. 600.0 V / DC
Alternating voltage ..........................max. 600.0 V / AC
Direct current ..................................max. 10.00 A / DC
Alternating current ..........................max. 10.00 A / AC
Resistance ......................................max. 40.00 MΩ
Capacitance ....................................max. 100.0 uF
Operating temperature ...................0 to 40 °C
Storage temperature .......................-10 to +50 °C
Operating/storage humidity ............ 0 ˚C to 30 ˚C: ≤75 % RH (non-condensing)
30 ˚C to 40 ˚C: ≤ 50 % RH (non-condensing)
Operating altitude ...........................max. 2000 m (above sea level)
Dimensions (W x H x D): ................76.5 x 157.5 x 40 mm
Weight ............................................approx. 262 g (without battery)
58