g) AC voltage measurement
Range
Resolution
Accuracy
400.0 mV
0.1m V
± (1.5 % + 8)
4.000 V
0.001 V
± (1.2 % + 6)
40.00 V
0.01 V
± (1.2 % + 6)
400.0 V
0.1 V
± (1.2 % + 6)
600 V
1 V
± (1.5 % + 4)
• Input impedance: approx. 10 MΩ.
• True RMS display.
• Frequency response: 40 - 400 Hz.
• Accuracy guarantee range: 5~100% of range, short circuit allows least significant digit
<5.
• Non-sinusoidal waveforms:
- When the crest factor is 1.0 to 2.0, the accuracy must be increased by 4.0 %.
- When the crest factor is 2.0 to 2.5, the accuracy must be increased by 5.0 %.
- When the crest factor is 2.5 to 3.0, the accuracy must be increased by 7.0 %.
• Input voltage: max. 600 Vrms.
h) Resistance measurement (Ω)
Range
Resolution
Accuracy
400.0 Ω
0.1 Ω
± (1.3 % + 5)
4.000 kΩ
1 Ω
± (1.3 % + 5)
40.00 kΩ
10 Ω
400.0 kΩ
100 Ω
4.000 MΩ
1 kΩ
± (1.5 % + 5)
40.00 MΩ
10 kΩ
± (2.5 % + 5)
Overload protection: 600 V
61