108
7
Resistance
Range
Resolution
Accuracy
600.0 Ω*
0.1 Ω
±(1.3% + 4)
6.000 KΩ
0.001 KΩ
±(1.2% + 7)
60.00 KΩ
0.01 KΩ
600.0 KΩ
0.1 KΩ
6.000 MΩ
0.001 MΩ
±(1.5% + 4)
60.00 MΩ
0.01 MΩ
±(2.7% + 7)
600 V overload protection
Measurement voltage: Approx. 1.0 V, measurement current approx. 0.7 mA
*Accuracy for measurement range ≤600 Ω was calculated after deducting lead
resistance from the REL function
8
Capacitance
Range
Resolution
Accuracy
6.000 nF*
0.001 nF
±(4.4% + 9)
60.00 nF*
0.01 nF
±(3.2% + 9)
600.0 nF*
0.1 nF
±(3.2% + 5)
6.000 µF
0.001 µF
60.00 µF
0.01 µF
600.0 µF
0.1 µF
6.000 mF
0.001 mF
±(4.4% + 5)
60.00 mF
0.01 mF
±(7.0% + 5)
600 V overload protection
*Accuracy for measurement range ≤600 nF only applies when the REL function
is used