In FL mode the display will show the following values:
c) Unit

f) FL indicator

e) Flow rate

4. 

Press the RESET button to set the value. The first digit starts flashing. Press the MODE button repeatedly 

to set the value.

5. Press the RESET button to move to the next digit. Set the value with the MODE button.
6. To save the value and return to normal mode, press and hold the MODE button for 3 seconds.

The kg, l and h values automatically adapt to the preset value. In normal mode, press the MODE 

button to show the desired value.

1.00 l or 0.85 kg is the lowest flow rate that can be set.
9.99 l or 8.54 kg is the highest flow rate that can be set.

If you exceed/underrun the maximum or minimum value during setting, the maximum or minimum 

value, respectively, will be saved automatically.

7. To discard the changes and return to normal mode, press and hold the RESET button for 3 seconds.

OIL LEVEL COUNT-DOWN

1. To store the oil level in the oil consumption indicator, press the MODE button repeatedly in normal mode 

until the desired unit (l or kg) shows up on the display.

2. Press and hold the OIL button for 3 seconds to switch to the oil level mode and set the oil level in the 

desired unit (l or kg). When you press and hold the OIL button for 3 seconds while the unit is set to h in 

normal mode, the unit in oil level mode will become l.

3. The display view will switch to oil level mode:

Oil level mode

g

h

c

In oil level mode the display will show the following values:
c) Unit

h) Oil level

g) ON/OFF indicator

4. 

Press the RESET button to set the value. The first digit of the oil level indicator (h) starts flashing. Press 

the MODE button repeatedly to set the value.

5. Press the RESET button to move to the next digit. Set the value with the MODE button.

The maximum oil level is 100,000 l or 85,470 kg.

6. For the countdown, the ON/OFF indicator has to be set to ON. If required, press the OIL button while the 

digit is still flashing to switch the ON/OFF indicator (g) to ON.

7. To save the value and return to normal mode, press and hold the MODE button for 3 seconds.
8. To discard the change and return to normal mode, press and hold the RESET button for 3 seconds.
9. To set the oil consumption indicator to 100%, press the RESET button and OIL button simultaneously.
10. 

  When the oil level has fallen to 10% (10 kg, 10 l, 1 h), the indicator will flash at a frequency of 4 times 

0.5 seconds, with a 3-second pause.

11. 

  When the oil level has reached 0%, the indicator will flash permanently.

 Legal notice

These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7  

(www.voltcraft.de).

All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing 

systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.

© Copyright 2012 by Voltcraft®

DEACTIVATE OIL LEVEL COUNT-DOWN

1. Switch to oil level mode (see “Oil level count-down”).

Oil level mode

In oil level mode the display will show the following values:
c) Unit

h) Oil level

g) ON/OFF indicator

2. 

Press the RESET button. The first digit of the oil level indicator (h) starts flashing.

3. Press the OIL button to set the ON/OFF indicator (g) to OFF.
4. To save the setting and return to normal mode, press and hold the MODE button for 3 seconds.
5. To discard the change and return to normal mode, press and hold the RESET button for 3 seconds.
6. To set the up counter to zero, press the MODE and RESET button simultaneously in normal mode.

The count-down has to be deactivated for each unit (h, kg or l) separately. To do this, switch to oil level 

mode, while the desired unit is shown, and set the ON/OFF indicator to OFF.

DISPOSAL

a)  Product

Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory 

regulations.
Remove any inserted (rechargeable) batteries and dispose of them separately from the product.

b)  (Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/rechargeable 

batteries. Disposing of them in the household waste is prohibited.

Contaminated (rechargeable) batteries are labelled with this symbol to indicate that disposal 

in the domestic waste is forbidden. The designations for the heavy metals involved are: Cd = 

Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the trash 

icon on the left).
Used (rechargeable) batteries can be returned to collection points in your municipality, our stores 

or wherever (rechargeable) batteries are sold. 

You thus fulfil your statutory obligations and contribute to the protection of the environment.

TECHNICAL DATA

Power supply (Display) ..........................................  1 x lithium battery, type CR2450
Power consumption ...............................................  <90  µA
Input voltage ..........................................................

 100 − 240 V/AC

LCD indicating range (up counter) .........................  0 to 999999,99
LCD indicating range (down counter) ....................  100000 to 0
Weight ...................................................................  95  g
Installation dimensions ..........................................   68 x 34 mm
Dimensions (W x H x D) ........................................  74 x 37 x 87 mm

Summary of Contents for DOM-100

Page 1: ...Copyright 2012 by Voltcraft V1_1212_02 HL WICHTIGER HINWEIS VERSION 12 12 DOM 100 L VERBRAUCHSANZEIGE BEST NR 10 33 33 Sehr geehrte Kundin sehr geehrter Kunde Untenstehend finden Sie einige nderungen...

Page 2: ...tions techniques et de l quipement Copyright 2012 by Voltcraft V1_1212_02 HL BELANGRIJKE INFORMATIE VERSIE 12 12 DOM 100 MONITEUR DE NIVEAU DE FUEL BESTELNR 10 33 33 Geachte klant De gebruiksaanwijzin...

Page 3: ...passungs und Reparaturarbeiten ausschlie lich von einem Fachmann bzw einer Fachwerkstatt durchf hren Sollten Sie sich ber den korrekten Anschluss bzw Betrieb nicht im Klaren sein oder sollten sich Fra...

Page 4: ...ge permanent Impressum Diese Bedienungsanleitung ist eine Publikation von Voltcraft Lindenweg 15 D 92242 Hirschau Tel Nr 0180 586 582 7 www voltcraft de Alle Rechte einschlie lich bersetzung vorbehalt...

Page 5: ...e performed exclusively by an expert or at a qualified shop If you are not sure about the correct connection or use or if questions arise which are not covered by these operating instructions please d...

Page 6: ...Legal notice These operating instructions are a publication by Voltcraft Lindenweg 15 D 92242 Hirschau Germany Phone 49 180 586 582 7 www voltcraft de All rights including translation reserved Reprodu...

Page 7: ...cordement de l appareil Tout entretien ajustement ou r paration ne doit tre effectu que par un sp cialiste ou un atelier sp cialis En cas de doute quant au raccordement correct de l appareil de son ut...

Page 8: ...rmations l gales Ce mode d emploi est une publication de la soci t Voltcraft Lindenweg 15 D 92242 Hirschau Allemagne T l 49 180 586 582 7 www voltcraft de Tous droits r serv s y compris de traduction...

Page 9: ...aat Onderhoud aanpassingen en reparaties mogen alleen uitgevoerd worden door een expert of in een daartoe bevoegde winkel Indien u vragen heeft over de correcte aansluiting of het gebruik of als er pr...

Page 10: ...l 0 bereikt blijft de weergave knipperen Colofon Deze gebruiksaanwijzing is een publicatie van de firma Voltcraft Lindenweg 15 D 92242 Hirschau Duitsland Tel 49 180 586 582 7 www voltcraft de Alle rec...

Reviews: