background image

b) Battery information

•  Always ensure that the battery is connected in the correct polarity.
•  Leaking or damaged batteries may cause acid burns if they come into contact 

with your skin. Always use suitable protective gloves when handling damaged 

batteries.

•  Batteries must be kept out of the reach of children. Do not leave batteries lying 

around, as there is a risk that children or pets may swallow them.

•  Batteries must not be dismantled, short-circuited during measurements or thrown 

into  flames.  Never  recharge  non-rechargeable  batteries.  This  may  cause  an 

explosion!

Product overview

MB-701

MB-702

4

3

2
1

2

1

4

3

1  Negative contact (on contact tab)

2  Positive battery contact (on contact tab)

3  Positive 4 mm contact plug

4  Negative 4 mm contact plug

Operation

a) Connecting the contacts to the battery/batteries

Fig.1

• 

Insert the flexible contact tabs between the 

battery and the battery contacts in the battery 

compartment of the device that you want to 

test. Ensure that they are connected in the 

correct polarity. Connect the positive terminal 

on the contact tab to the positive battery 

terminal. Connect the negative terminal 

on the contact tab to the negative battery 

terminal

• 

Ensure  that  the  contact  is  connected 

properly. Clean the contact surfaces if there 

are signs of corrosion or oxidation.

  The battery/batteries and the connection terminals are shown above. In practice, it is 

best to leave the battery/batteries in the battery compartment of the device that you 

want to test and carefully slide the flexible contact tabs between the contacts.

 Operating instructions

Measuring adapter MB-701
Measuring adapter MB-702

Item no. 1674851
Item no. 1674854

Intended use

This product is designed to measure voltage and current on batteries/rechargeable batteries 

under load. It can be used to take measurements on devices that are powered by AAA, AA, 

D or N batteries. 9 V block batteries can also be tested in appropriate circumstances. The 

battery test cables connect to a suitable measurement device (e.g. multimeter) to allow you to 

take measurements. Up to three measuring adapters are required to use all of the product's 

functions.
This product is intended for indoor use only. Do not use it outdoors. Contact with moisture (e.g. 

in bathrooms) must be avoided under all circumstances.
For safety purposes, you must not rebuild and/or modify this product. Using the product for 

purposes other than those described above may damage the product. In addition, improper 

use can cause hazards such as a short circuit or fire. Read the instructions carefully and store 

them in a safe place. Only make this product available to third parties together with its operating 

instructions.

This  product  complies  with  statutory,  national  and  European  regulations. All  company  and 

product names are trademarks of their respective owners. All rights reserved.

Package contents

•  Measuring adapters (with test leads)
•  Operating instructions

Up-to-date operating instructions           

Download the up-to-date operating instructions at www.conrad.com/downloads or scan the QR 

code shown. Follow the instructions on the website.

Explanation of symbols

  The symbol with an exclamation mark in a triangle is used to highlight important 

information in these operating instructions. Always read this information carefully.

  The arrow symbol indicates special information and advice on how to use the 

product.

Safety information

Read the operating instructions and safety information carefully. If you do 

not follow the safety information and information on proper handling in these 

operating instructions, we will assume no liability for any resulting personal 

injury or damage to property. Such cases will invalidate the warranty/

guarantee.

a) General information

•  The device is not a toy. Keep it out of the reach of children and pets.
•  Do not leave packaging material lying around carelessly. This may become 

dangerous playing material for children.

• 

Protect the product from extreme temperatures, direct sunlight, strong jolts, high 

humidity, moisture, flammable gases, vapours and solvents.

•  Do not place the product under any mechanical stress.
•  If it is no longer possible to operate the product safely, take it out of operation and 

protect it from any accidental use. Safe operation can no longer be guaranteed 

if the product:

 - is visibly damaged, 
 - is no longer working properly, 
 -

has been stored for extended periods in poor ambient conditions or 

 - has been subjected to any serious transport-related stress.

•  Please handle the product carefully. Jolts, impacts or a fall even from a low height 

may damage the product.

•  Always observe the safety information and operating instructions of any other 

devices which are connected to the product.

•  Consult a technician if you are not sure how to use or connect the product, or if 

you have concerns about safety.

• 

Maintenance, modifications and repairs may only be carried out by a technician or 

a specialist repair centre.

•  If you have questions which remain unanswered by these operating instructions, 

contact our technical support service or other technical personnel.

Summary of Contents for MB-701

Page 1: ...Messadapter Eine Verwendung ist nur in geschlossenen R umen also nicht im Freien erlaubt Der Kontakt mit Feuchtigkeit z B im Badezimmer u ist unbedingt zu vermeiden Aus Sicherheitsgr nden d rfen Sie...

Page 2: ...schnitt a Kontakte an die Batterie n anschlie en beschrieben Sie ben tigen in diesem Fall neben den zwei Multimetern auch noch einen zweiten und dritten Messadapter Verbinden Sie die drei Messadapter...

Page 3: ...mage the product In addition improper use can cause hazards such as a short circuit or fire Read the instructions carefully and store them in a safe place Only make this product available to third par...

Page 4: ...t you want to measure Follow the instructions in section a Connecting the connecting the contacts to the battery batteries to establish the connection In addition to two multimeters you will also requ...

Page 5: ...interdite Tout contact avec l humidit par ex dans une salle de bain est viter absolument Pour des raisons de s curit toute transformation et ou modification du produit est interdite Si vous utilisez...

Page 6: ...a ou les pile s En plus des deux multim tres vous avez dans ce cas galement besoin d un deuxi me et troisi me adaptateur de mesure Raccordez les trois adaptateurs de mesure deux multim tres appropri s...

Page 7: ...kamers e d dient absoluut te worden vermeden Om veiligheidsredenen zijn er geen aanpassingen en of wijzigingen aan dit product toegestaan Als het product voor andere doeleinden wordt gebruikt dan de h...

Page 8: ...acten aan de batterij en aansluiten In dit geval heeft u naast de twee multimeters ook nog een tweede en derde meetadapter nodig Verbind de drie meetadapters overeenkomstig de afbeelding met twee gesc...

Reviews: