background image

Optional switch:

+

5 V

RC

GND

c) (Optional) PM/USB adaptor for PM-60/20A connection

Connect the PM/USB adaptor for PM-60/20A (not included) to the PM-USB adaptor socket “Data” for data retrieval 

and analysis.

OPERATION

a) Measurement

1.  Make sure all the wires are properly connected and not short-circuited.
2.  Switch on the power source.
3.  During boot up, the firmware version and factory preset data port mode will be shown on the display.
4.  The reading will be shown on the display after the boot up.

9.12V    1.00A

60.0Ah  9.12W

1

2

3

4

1.  Voltage (V)
Showing the present voltage in Volt (V).

2.  Current (A)
Showing the present current in ampere (A).

3.  Power (W)
Showing the present power consumption in watt (W).

The power reading will be temporary hidden when the cyclic value display is showing the running time.

4.  Cyclic value display
The cyclic value display shows one of the readings and then jump to the next one every three seconds in the below order: 
Ampere-hour (Ah) > Watt / hour (Wh) > Peak voltage (Vp) > Peak current (Ap) >  

Peak power (Wp) > Minimum voltage (Vm) > Minimum current (Am) > Running time

To stop at a certain reading, press the RESET button briefly. Press again to start the rotation again.

Charge (Ah):
Showing the total electric charge supplied to the load in Ampere-hours since the wattmeter was connected.

Energy consumed (Wh):
Showing the total energy consumed by the load in Watt-hours since the wattmeter was connected.

Peak voltage (Vp):
Showing the peak voltage of the measurement session (from the moment that the wattmeter was started to present 

or from last reset to present).

Peak current (Ap):
Showing the peak current of the measurement session (from the moment that the wattmeter was started to present 

or from last reset to present).

Peak power (Wp):
Showing the peak power of the measurement session (from the moment that the wattmeter was started to present 

or from last reset to present).

Minimum voltage (Vm):
Showing the minimum voltage of the measurement session (from the moment that the wattmeter was started to 

present / from last reset to present).

Minimum current (Am):

 Legal notice

These operating instructions are a publication by Voltcraft®, Lindenweg 15, D-92242 Hirschau/Germany, Phone +49 180/586 582 7  

(www.voltcraft.de).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing 

systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.

© Copyright 2013 by Voltcraft®

Showing the minimum current of the measurement session (from the moment that the wattmeter was started to 

present / from last reset to present).

Running time
Shows the duration of the measurement (from the moment when the wattmeter has been turned on/reset, until the 

current point in time).

b) Reset measurement data

There are two ways to reset the measurement data and to clear the memory:
•  press and hold the RESET button until you see the message “Press again for 5 sec to reset”, release the RESET 

button and then hold again for five seconds, or;

•  use the optional switch set in “CONNECTION - b) (Optional) External power source connection”.  Press and hold 

the switch for three seconds and release it.

c) Data retrieval

Refer to the manual of the PM/USB adaptor for PM-60/20A.

DISPOSAL

Electronic devices are recyclable waste and must not be disposed of in the household waste.
At the end of its service life, dispose of the product according to the relevant statutory regulations.

TECHNICAL DATA

Operating voltage ....................... 5 – 60 V/DC (from the circuit under testing) 
 

5 – 60 V/DC (from an external power source)

Current consumption .................. 12 mA (from the circuit under testing)
 

9 – 12 mA (from an external power source)

Logging rate ................................ 3 minutes
Logging duration ......................... max. 75 hours
Memory ....................................... 1500 sets of data
Measuring range ......................... Current: 

0 – 20 A

 

 

20 – 30 A (limited to max. 30 mins)

 

 

30 – 60 A (limited to max. 5 seconds)

 

Voltage: 

5 – 60 V (powered by the circuit under testing)

 

 

0 – 60 V (powered by an external power source)

 

Charge:  

0 – 99999 Ah

 

Power: 

0 – 3600 W

 

Energy:  

0 – 9999.9 KWh

Resolution ................................... Current: 

0.01 A

 

Voltage: 

0.01 V

 

Charge: 

0.01 Ah (<1000 Ah)

 

 

0.1 Ah (≥1000 Ah and <10000 Ah)

 

 

1 Ah (≥10000 Ah)

 

Power: 

0.1 W

 

Energy: 

0.1 Wh

Environment condition ................ 0 to +40 ºC, non-condensing humidity (Operating)
 

-10 to +60 ºC (Storage)

Dimensions (W x H x D) ............. 75 x 45 x 23 mm
Weight ........................................ 83 g

Summary of Contents for PM-60V/20A

Page 1: ...el ber die Arbeitsweise die Sicherheit oder den Anschluss des Produktes haben Lassen Sie Wartungs Anpassungs und Reparaturarbeiten ausschlie lich von einem Fachmann bzw einer Fachwerkstatt durchf hren...

Page 2: ...pitzenspannung der Messung an von dem Moment als das Leistungsmessger t eingeschaltet wurde bis zum aktuellen Zeitpunkt vom letzten R cksetzen bis zum aktuellen Zeitpunkt Maximaler Strom Ap Zeigt den...

Page 3: ...electric shock if you touch electric conductors b Miscellaneous Consult an expert when in doubt about operation safety or connection of the device Maintenance modifications and repairs are to be perf...

Page 4: ...ons are a publication by Voltcraft Lindenweg 15 D 92242 Hirschau Germany Phone 49 180 586 582 7 www voltcraft de All rights including translation reserved Reproduction by any method e g photocopy micr...

Page 5: ...de tension sont d j suffisantes pour provoquer un risque d lectrocution mortel en cas de contact avec les conducteurs lectriques b Divers Adressez vous un technicien sp cialis si vous avez des doutes...

Page 6: ...quelle qu elle soit p ex photocopie microfilm saisie dans des installations de traitement de donn es n cessite une autorisation crite de l diteur Il est interdit de le r imprimer m me par extraits Ce...

Page 7: ...an elektrische geleiders een levensgevaarlijke elektrische schok krijgen b Diversen Raadpleeg een expert wanneer u twijfelt over het juiste gebruik de veiligheid of het aansluiten van het apparaat Ond...

Page 8: ...582 7 www voltcraft de Alle rechten vertaling inbegrepen voorbehouden Reproducties van welke aard dan ook bijvoorbeeld fotokopie microverfilming of de registratie in elektronische gegevensverwerkings...

Reviews: