background image

DISPOSAL

7. 

General

In order to preserve, protect and improve the quality of environment, protect human 
health and utilise natural resources prudently and rationally, the user should return 
unserviceable product to relevant facilities in accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately 
and not as municipal waste.

Batteries / rechargeable batteries

The user is legally obliged (battery regulation) to return used batteries and 
rechargeable batteries. Disposing used batteries in the household waste is 
prohibited!
 Batteries/ rechargeable batteries containing hazardous substances are 
marked with the crossed-out wheeled bin. The symbol indicates that the product 
is forbidden to be disposed via the domestic refuse. The chemical symbols for the 
respective hazardous substances are Cd = Cadmium, Hg = Mercury, Pb = Lead.
You can return used batteries/ rechargeable batteries free of charge to any collecting 
point of your local authority, our stores or where batteries/ rechargeable batteries are 
sold.

Consequently you comply with your legal obligations and contribute to environmental 
protection!

TECHNICAL DATA

8. 

Operating voltage:

4.5 V/DC

Battery type:

3 x AAA

Current consumption:

7.5 mA

Weighing capacity:

Gram

500 g

Ounce

18 oz

Pennyweight 322 dwt

Resolution:

Gram

0.05 g

Ounce

0.002 oz

Pennyweight 0.05 dwt

Automatic shut-off time:

after 6 minutes

Operating temperature: 

+5 to +35 ºC, < 90 % RH

Storage temperature:

0 to +50 ºC, < 90 % RH

Display dimensions (W x H): 31 x 14 mm

Dimensions (W x H x D):

82 x 30 x 140 mm

Weight:

133 g

 OPERATING INSTRUCTIONS

Version 12/10

PS-500C POCKET SCALE

Item No. 12 30 69

INTENDED USE

1. 

This product is designed to weigh objects of up to 500 g in weight. The weight can also be 
displayed in ounces (oz) or pennyweight (dwt). In addition, the product can also display the 
number of units weighed. Power is supplied via three batteries (type AAA). The product should 
only be used in dry indoor areas. The product is not suitable for medical or commercial uses.
For safety and approval purposes (CE), you must not rebuild and/or modify this product. If you 
use the product for purposes other than those described above, the product may be damaged. In 
addition, improper use can cause hazards such as short circuiting, fi re, electric shock etc. Read 
the instructions carefully and keep them. Make this product available to third parties only together 
with its operating instructions.

DELIVERY CONTENT

2. 

Pocket scale

• 

3 x battery (type AAA)

• 

Operating instructions

• 

SAFETY INSTRUCTIONS

3. 

Read the operating instructions carefully and especially observe the safety 
information. If you do not follow the safety instructions and information 
on proper handling in this manual, we assume no liability for any resulting 
personal injury or damage to property. Such cases will invalidate the warranty/
guarantee.

Persons / Product

The product is not a toy. Keep it out of the reach of children and pets.

• 

Do not leave packaging material lying around carelessly. These may become dangerous 

• 

playing material for children.
Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity, 

• 

moisture, fl ammable gases, vapours and solvents.
Do not place the product under any mechanical stress.

• 

If it is no longer possible to operate the product safely, take it out of operation and protect it 

• 

from any accidental use. Safe operation can no longer be guaranteed if the product:

is visibly damaged, 

 -

is no longer working properly, 

 -

has been stored for extended periods in poor ambient conditions or 

 -

has been subjected to any serious transport-related stresses.

 -

Handle the product carefully. Jolts, impacts or a fall even from a low height can damage the 

• 

product.
Operation in environments with strong electromagnetic radiation might involve deviations of 

• 

the indicated values.
Loads (weighing object) should not be left resting permanently on the scale. This might 

• 

damage the measuring mechanism.

Batteries

Correct polarity must be observed while inserting the batteries.

• 

Batteries should be removed from the product if it is not used for a long period of time to 

• 

avoid damage through leaking. Leaking or damaged batteries might cause acid burns when in 
contact with skin, therefore use suitable protective gloves to handle corrupted batteries.
Batteries must be kept out of reach of children. Do not leave the battery lying around, as there 

• 

is risk, that children or pets swallow it.
All the batteries should be replaced at the same time. Mixing old and new batteries in the 

• 

product can lead to battery leakage and product damage.
Batteries must not be dismantled, short-circuited or thrown into fi re. Never recharge non-

• 

rechargeable batteries. There is a risk of explosion!

Miscellaneous

Consult an expert when in doubt about operation, safety or connection of the product.

• 

Maintenance, modifi cations and repairs are to be performed exclusively by an expert or at a 

• 

qualifi ed shop.
If you have queries about handling the product, that are not answered in this operating 

• 

instruction, our technical support is available under the following address and telephone 
number: Voltcraft

®

, 92242 Hirschau, Lindenweg 15, Germany, phone 0180 / 586 582 7

INSERTING / REPLACING BATTERIES

4. 

Remove the battery compartment cover at the rear of the product.

1. 

Insert three batteries (type AAA), observing their correct polarity. Observe the polarity markings 

2. 

in the battery compartment. The fabric strip should be positioned under the batteries, allowing 
batteries to be easily taken out when they are replaced.
Close the battery compartment again.

3. 

Replace the batteries when “Lo” appears on the display.

OPERATION

5. 

General

Place the scales on a stable, horizontal and level surface.

1. 

Lift the cover of the scales.

2. 

Press the button ON/OFF to switch the scales on. All display elements will be displayed for 

3. 

approx. three seconds, followed by the value “0“ being displayed. If another value is shown, 
press the button TARE.
Press the button MODE to select the unit: grams (g), ounces (oz), pennyweight (dwt) or 

4. 

quantity (pcs). A horizontal line will appear next to the selected unit.
Place the object to be weighed carefully on the weighing platform. The object’s weight will be 

5. 

shown on the display.
Press the button ON/OFF to switch the scales off. Alternatively, the scales will switch off 

6. 

automatically after idling for approx. six minutes.

Tare function

The tare function is intended for net measuring using a weighing container. The tare function 
offsets the weight of the used weighing container so that the display shows only the net weight 
of the measuring object.

Switch on the scale and place the empty weighing container (bowl, basket, etc.) on the 

1. 

weighing platform and wait until the display is stabilized.
Press the button TARE and the display shows “0.00” despite of the weighing container resting 

2. 

on the scale.
Put the object to be measured into the weighing container. The display indicates the net 

3. 

weight of the object.
If you would like to measure without weighing container, remove it from the weighing platform 

4. 

and press the button TARE. Any tarred value will be displayed as a negative number once all 
weight is removed from the scale.

The weighing capacity of the weigh scale includes the weighing container. Therefore, 
it is recommended to use a weighing container which is as light as possible.

Counting units

This function determines the quantity of units of an equal weight.

Press the button MODE repeatedly until the horizontal line to the right of the display appears 

1. 

next to “pcs”.
Press the button PCS to set the reference unit number (10, 20, 50, 100, 200).

2. 

Place exactly as many objects on the weighing platform as set as the reference unit number.

3. 

Press the button MODE. The display will show the number of units.

4. 

Now place the objects to be counted on the weighing platform. The display will show the 

5. 

number of units.

The reference value will be stored even after the scales have been turned off. 
However, if you want to count other types of objects, proceed as described above.

Calibration

To calibrate the scales you need a standard weight of 500 g (not included in delivery).

When the scales are turned off, press and hold the button TARE until the display shows a 

1. 

four- to fi ve-digit value (between 4000 – 22000).
Wait until this value has stabilized and then press the button TARE again. The display will 

2. 

show the value “500”.
Place the standard weight on the weighing platform and press the button TARE. First “CAL“ 

3. 

and then “PASS“ will appear on the display. This means that the calibration process has been 
completed.
Take the standard weight off the weighing platform and turn the scales off.

4. 

ERROR INDICATIONS

6. 

Indication Cause

Solution

- - - - - 

The weighing object exceeds the 
weighing range.

Remove the weighing object from the 
scale immediately.

Lo

The battery voltage is so low that the 
scale cannot function properly. 

Replace the batteries immediately.

Err

The data storage is damaged.

---

Out

The load cell is damaged.

---

These operating instructions are published by Voltcraft®, 
Lindenweg 15, D-92242 Hirschau/ Germany, Phone +49 180 586 582 7.
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming, or the 
capture in electronic data processing systems require the prior written approval by the editor. Reprinting, 
also in part, is prohibited. 
The operating instructions refl ect the current technical specifi cations at time of print. 
We reserve the right to change the technical or physical specifi cations.
© Copyright 2010 by Voltcraft®.

V2_1210_02-SB

Summary of Contents for PS-500C

Page 1: ...dern auf Lassen Sie Batterien nicht frei herumliegen da diese von Kindern oder Haustieren verschluckt werden könnten Alle Batterien sollten zum gleichen Zeitpunkt ersetzt werden Das Mischen von alten und neuen Batterien im Gerät kann zum Auslaufen der Batterien und zur Beschädigung des Produkts führen Nehmen Sie keine Akkus auseinander schließen Sie sie nicht kurz und werfen Sie sie nicht ins Feue...

Page 2: ...charge non rechargeable batteries There is a risk of explosion Miscellaneous Consult an expert when in doubt about operation safety or connection of the product Maintenance modifications and repairs are to be performed exclusively by an expert or at a qualified shop If you have queries about handling the product that are not answered in this operating instruction our technical support is available...

Page 3: ...uites ou des piles endommagées peuvent provoquer des brûlures acides lors d un contact avec la peau il convient donc d utiliser des gants de protection appropriés pour manipuler des piles usagées Maintenir les piles hors de portée des enfants Ne pas laisser de pile traîner un enfant ou un animal domestique pourrait en avaler une Remplacer toutes les piles en même temps Mélanger des piles neuves et...

Page 4: ... buiten bereik te worden gehouden van kinderen Laat de batterij niet rondslingeren Het gevaar op inslikken bestaat voor kinderen en huisdieren Alle batterijen dienen tegelijkertijd vervangen te worden Het mengen van oude met nieuwe batterijen in het product kan leiden tot batterijlekkage en beschadiging van het product Batterijen mogen niet worden ontmanteld kortgesloten of verbrand Probeer nooit ...

Reviews: