DC voltage range, overload protection 250 V
Range Accuracy
Note
10 V / 50 V / 100 V / 250 V
± 4%
Inner resistance 2 kOhm/V
AC voltage range (50/60Hz), overload protection 250 V
Range Accuracy
Note
10 V / 50 V / 100 V / 250 V
± 5%
Inner resistance 2 kOhm/V
Direct current range
Range Accuracy
Note
0.5 mA / 50 mA / 250 mA
± 4%
F500mA H 250V Flink
circuit-breaking capacity 1.5 kA
Resistance range, overload protection 250V
Range Accuracy
Note
x1k
± 4° angle over
the entire
scale range
Battery test
Range Accuracy
Note
1.5 V/ 9 V
not specified
Attenuation measurement dBm
Range Accuracy
Note
-20 to +50 dBm
not specified
Only available in the
V/AC measuring range
Acoustic continuity tester, overload protection 250V
Note
Measuring range approx.
<20
Ω
scale display is not
value compliant
Do not exceed the maximum permitted input values.
Never touch circuits or parts of circuits with voltages
greater than 25 V/AC rms or 35 V/DC! Danger to life!
53