22
a) Current clamp
1 Clamp
2 Setting wheel
3 Light button
4 LCD display
5 Battery compartment (back)
6 Hole for a strap
7
MAXH
button
8
HOLD
button
9 Opening lever
b) LCD display
Symbols
No.
Symbol
Control display/display
A
A
Control display - current
B
--
Measurement value
C
MAXH
Control display - maximum value
D
Control display - hold
E
Control display - battery
F
AC
Control display - alternating current
Resolution
Measurement range
Resolution
Accuracy
2
.
000 A~
1 mA
± (4 % + 30)
20
.
00 A~
10 mA
± (3 % + 10)
200
.
0 A~
100 mA
± (2.2 % + 9)
accuracy ± (% of the r display errors in counts). The accuracy is maintained
for one year at a temperature of +23 °C (± 5 °C) at a relative humidity of
≤75
%, non-condensing.