46
13. TECHNICAL DATA
Display ..................................................2000 counts (characters)
Measuring rate ......................................Approx. 2-3 measuring operations/second
Measuring converter AC .......................Actual effective value True RMS
Measuring line length ...........................Each approx. 90 cm
Measuring impedance .........................
>10 MΩ (V-range)
Measuring socket distance ..................19 mm
Voltage supply .....................................9 V block batteries (NEDA 1604, 6F22 or same build)
Operating conditions ............................0 to 30 °C (<75%rF)
..............................................................
30 to 40 °C (<50% rF)
Operating height ..................................max. 2000 m above sea level
Storage conditions ...............................-10 °C to +50 °C (<80% rF)
Weight .................................................approx. 200 g
Dimensions (LxWxH) ............................150 x 75 x 38 (mm)
Measuring category ..............................CAT III 600 V
Degree of contamination ......................2
Measurement tolerances
Statement of accuracy in ± (% of r display error in counts (= number of smallest points)). The accuracy is
valid for one year at a temperature of +23 °C ±5 °C, and at a relative humidity of less than 75%, non-condensing.
In an electromagnetically burdened environment up to 1V/m, the tolerance in the entire measured range increases
by +5% of the measured range. A measurement in an environment above 1 V/m is no longer permitted.