74
Capacitance
Range
Resolution
Accuracy
6.000 nF*
0.001 nF
±(5.0% + 10)
60.00 nF*
0.01 nF
±(5.0% + 5)
600.0 nF*
0.1 nF
6.000 µF
0.001 µF
60.00 µF
0.01 µF
600.0 µF
0.1 µF
6.000 mF
0.001 mF
±10%
60.00 mF
0.01 mF
600 V overload protection
*Accuracy for measurement range ≤600 nF only applies when the REL function is used
Frequency “Hz” (electronic)
Range
Resolution
Accuracy
≤9.999 Hz*
0.001 Hz
Not specified
10.00 Hz - 99.99 Hz
0.01 Hz
±(0.1% + 6)
100.0 Hz - 999.9 Hz
0.1 Hz
1.000 kHz - 9.999 kHz
0.001 kHz
10.00 kHz - 99.99 kHz
0.01 kHz
100.0 kHz - 999.9 kHz
0.1 kHz
1.000 MHz - 9.999 MHz
0.001 MHz
>10.00 MHz*
0.01 MHz
Not specified
*The specified frequency range is 10.00 Hz - 10 MHz
Signal level (without direct voltage component):
≤100 kHz: 200 mVrms - 20 Vrms
>100 kHz to 1 MHz: 500 mVrms - 20 Vrms
>1 MHz to 5 MHz: 500 mVrms - 20 Vrms
>5 MHz to 10 MHz: 900 mVrms - 20 Vrms
600 V overload protection
Pulse width/ pulse ratio (duty cycle)
Range
Resolution
Accuracy
0.1% - 99.9%
0.1%
±(3% + 6)
Overload protection: 600 V
Signal level (without direct voltage component):
≤100 kHz: 200 mVrms - 20 Vrms
Frequency range pulse width: ≤100 kHz