75
Temperature
Range
Resolution
Accuracy
-40 to 0 °C
1 °C
±(6.0% + 5)
0 to +100 °C
±(1.5% + 4)
+100 to +1000 °C
±(1.5% + 4)
>1000 to +1300 °C
Not specified
-40 to +32 °F
1 °F
±(6.0% + 9)
+32 to +212 °F
±(1.5% + 5)
+212 to +1832 °C
±(2.5% + 5)
>1832 to +2372 °F
Not specified
Overload protection: 600 V, Sensor input: Type K
Non-contact AC voltage detection (NCV)
Range
Frequency range
Indication
≥220 V
50 – 60 Hz
EF = No voltage detection
-
- -
- - -
- - - -
Signal strength not specified
Beep, not specified
Detection range approx.: ≤ 15 mm - 50 mm
Diode test
Test voltage
Resolution
Approx. 3.0 V/DC
0.001 V
Overload protection: 600 V; Test voltage: 2 mA typ.
Acoustic continuity tester
Measurement range
Resolution
600 Ω
0.1 Ω
≤10 Ω continuous tone; ≥100 Ω no tone
Overload protection: 600 V
Test voltage approx. 1 V
Test current 0.7 mA
Never exceed the maximum permitted input values. Do not touch any circuits or circuit compo-
nents if the circuit has voltages higher than 33 V AC RMS or 70 V DC. Danger of death!