Voltech Instruments
Induction hobs are operated with an enamelled steel pan, which contains
approximately half its capacity of water at room temperature, and
positioned at the centre of each cooking zone, in turn. Thermal controls are
adjusted to their highest setting.
The diameter of the base of the pan is to be at least the diameter of the
cooking zone. The smallest pan complying with this requirement is used.
The maximum concavity of the bas of the pan is 3D/1000 where D is the
diameter of the flat area of the base of the pan. The base of the pan is not to
be convex.
The concavity is checked at room temperature using an empty pan.
6.7.
F
LICKER
T
EST
C
ONDITIONS
IEC61000-3-3 2001
General test conditions
The test conditions for the measurement of flicker are given in the
following clauses. For equipment not mentioned in Specific test conditions
list, controls or automatic programmes shall be set to produce the most
unfavourable sequence of voltage changes using only those combinations
of controls and programmes that are mentioned by the manufacturer in the
instruction manual, or are otherwise likely to be used. Particular test
conditions for equipment not included in the Specific conditions list are
under consideration.
The equipment shall be tested in the condition in which it is supplied by the
manufacturer. Preliminary operation of motor drives may be needed before
the tests to ensure that results corresponding to those of the normal use are
obtained.
•
For motors, locked-rotor measurements may be used to determine
the largest rms voltage change, dmax, occurring during motor
starting.