Never  touch

  or  manipulate  the  components  of  the 

electronic  PCB  with  hands  and  without  any  protection 
against  electrostatic  discharges  (ESD).  They  are  highly 
destructive  for  most  of  the  parts  and  they  can  cause 
expensive breakdown. 
«

Main  protective  earthing  terminal

» symbol. Connect the 

earth cables from the installation to this terminal. 
«

Earth  bonding  terminal

»  symbol.  Connect  the  earth 

cables from the load and the external battery cabinet to this 
terminal. 

    

«

Notes of information

» symbol. Additional topics that 

complement the basic procedures. These instructions are 
important for the equipment use and its optimum efficiency. 

    

It is mandatory to use insulated gloves to prevent possible 

electrical discharges when manipulating the connections related 
to batteries. 
It  is  mandatory  to  wear  insulated  shoes  to  prevent  possible 
electrical discharges when manipulating the connections which 
are related to batteries. 
It  is  mandatory  to  wear  protective  glasses,  tight  and 
appropriate work clothes  without hanging parts. 

    

Obligation  to turn  off  the  power  supply  or loads 

connected to the output. 

    

Read carefully the instructions in the manual. 

    

Smoking, fire or any actions that make sparks around the 

batteries are prohibited. 

 

To pull connecting cables is prohibited. Use the suitable mediums 
to unplug the connections from terminals. 
To touch with bare hands is prohibited due to risk of electric 
shock when contacting with  low potential  parts. To open, 
manipulate  the  components  inside  the  equipment  and/or 
terminals  and  battery  connections  are  prohibited  for  non-
authorized and non-qualified personnel. 
To  randomly  turn  on  the  switches  or  protections  is 
prohibited. All maneuvers should be done according to the 
instruction manual. 
In case that the acid in the batteries contact with parts of the 
body, wash the contacted areas with plenty of water and go to 
the nearest medical service. 

Preservation  of  the  environment

:  The  presence  of  this 

symbol  in  the  product  or  in  their  associated  documentation 
states that, when the life cycle of product expires, it cannot 
be disposed together with the domestic residuals. In order to 
avoid  possible  damages  to  the  environment,  separate  this 
product from other residuals and recycle it suitably. The users 
can  contact  with  their  provider  or  with  the  pertinent  local 
authorities to get the information of how and where they can 
recycle and/or dispose the product correctly. 
Any  packaging  material  must  be  recycled  in  accordance 
with the legal norms applicable to each country where the 
equipment is installed. 
Alternating current a.c.. 

    

Direct current d.c.. 

 

2.1.2.  For more information and/or help.

 

 

For more information and/or help of your specific unit, request it to 
our Service and Technical Support 

(S.T.S.)

.

 

 

2.2. 

SAFET Y INSTRUCTIONS.

 

 

•    It is required to  check the installation information on the nameplate. 
•  

Please remember  that  the 

UPS  is  an  electrical 

energy generator

, so the 

end-user must take all the 

needed cautions against direct and indirect 
contact

.

 

Its  power  supply  relies  on  the  batteries,  and  AC  mains, 
which  are  included  or  excluded  in  the  case  or  cabinet  of  the 
electronic parts of the equipment depending on the model and/ 
or extended autonomies. 
When the equipment is ON, and the batteries are connected to the 

equipment  and  its  protections,  if  any,  are  turned  “On,”  the  fact 
that the UPS is connected or not connected to mains is irrelevant, 
and  neither  is  the  protections  of  mains.  The  outlets  or  output 

terminals will supply voltage when there is energy in the battery set. 

•    

Compliance as  regards  to  “Safety  instructions“  is  

mandatory,  being  the  user  the  legal  responsible 

regarding 

to its observance and application. Read them carefully and 

follow  the  stated  steps  in  the  established  order,  keep  them  for 
future consultations that may arise. 

•  

If the 

instructions are not in total or partial understood 

and in special those ones referred to safety, do not 

carry 

on with the installation or commissioning tasks, because there 

could be a at a 

risk of your or other persons’ safety

, being able 

to  make 

serious  injuries  even  the  death

,  also  it  can  cause 

damages to the equipment and/or loads and installation

•    

The local electrical regulations and the different  
restrictions  of  the  client’s  site  can  invalidate  some 

recommendations included in the manuals. When discrepancies 
exist, the user has to comply with the local regulations. 

•  

This equipment must  be 

installed  by  qualified 

personnel  and  for  personnel with  no specific 
training

, just act with the help of this manual. 

A  person  is  defined  as 

qualified

,  if  he  has  experience  in 

assembling, commissioning and perfect control operating of the 
equipment, if (s)he has the requirements to do the job and if (s)he 
has read and understand all the things described in this manual, 
in  particular  the  safety  indications.  Such  preparation  is 
considered valid if it is certified by our 

(S.T.S.) 

only. 

•    Warning labels have to be placed in all primary switches, installed in 

areas far away from the equipment, in order to warn the electrical 
maintenance personnel of the presence of a UPS in the circuit. 
The label shall contain the following text or an equivalent one: 

 

Before operating in the circuit.

 

 

Isolate the Uninterruptible Power Supply (UPS).

 

 

Check  the  vo

ltage  of  al

l  terminals,  including  the 

 

earth main protective earth.

 

 

Risk of UPS backfeed voltage.

Summary of Contents for Taurus UPS-10

Page 1: ...7 Touch LCD Online UPS 208V 7 5K 60KVA 400V 10K 200KVA Uninterruptible Power Supply System User Manual...

Page 2: ...X4 5 2 2 Connection of separate static bypass line terminals X14 a X17 UPS B version only 5 2 3 Connection to the output terminals X6 to X9 5 2 4 Connection to the battery terminals of the equipment...

Page 3: ...hand during the installation and commissioning procedures In the next pages the equipment or unit and S T S terms are referred to the Uninterruptible Power Supply UPS and Service and Technical Support...

Page 4: ...urrent a c Direct current d c 2 1 2 For more information and or help For more information and or help of your specific unit request it to our Service and Technical Support S T S 2 2 SAFETY INSTRUCTION...

Page 5: ...any installation task Do not store install or expose the equipment in corrosive wets warm dusty environments or with conductive parts and never outdoors The best location for installation should be c...

Page 6: ...ration Once the respective actions are completed recover the equipment to it was with the protection cover put back and front door closed To shut down the equipment completely follow the instructions...

Page 7: ...ied personnel who will be responsible for applying the safety and EMC regulations and standards controlling the particular installations and the place where the product is destined 2 2 3 Safety warnin...

Page 8: ...particular due to this last period and safety reasons the energy generator should be handled with care especially to prevent batteries from unnecessarily discharging during these periods of time When...

Page 9: ...ers EN IEC 60950 1 IT equipment Safety Part 1 General requirements EN IEC 62040 2 Uninterruptible power supply UPS Part 2 EMC requirements The manufacturer s responsibility excluded the event of any m...

Page 10: ...of the same family because the necessary electronic kit is included Connection in parallel can be done at any time when the upgrading requirements are needed to increase the supplied power of the equi...

Page 11: ...from 7 5 to 30 kVA LV 10to 60 kVA HV with or without separate static bypass line B Fig 2 UPSfrontview from 40 to60kVA LV 80 to120kVA HV without separate static bypass and 40 kVA LV 80 kVA HV with sep...

Page 12: ...CD Touch Screen View 1 Equipment with extended back up time only Fig 4 UPS Front view with door opened 7 5KVA to 20KVA LV 10KVA to 40KVA HV models Fig 5 UPS Front view with door opened 30KVA LV 60KVA...

Page 13: ...iew with door opened 7 5KVA to 10KVA LV 10KVA to 20KVA HV models with separate static bypass line UPS B models Fig 7 UPS Front view with door opened 15KVA LV 30KVA HV models with separate static bypas...

Page 14: ...12 Fig 8 UPS Front view with door opened models 20KVA LV 40KVA HV with separate static bypass line UPS B models Fig 9 UPS front view with door opened models 40kVA LV 80KVA HV...

Page 15: ...13 Fig 10 UPS front view with door opened models 50 and 60 kVA LV 100 and 120 kVA HV without separatestatic bypass line...

Page 16: ...14 Fig 11 UPS front view with door opened models 80 and 100 kVA LV 160 and 200 kVA HV without separatestatic bypass line...

Page 17: ...15 Q8 X47 X49 X48 BF X5 PR X10 Fig 12 Battery cabinet front view No 1 with door closed Fig 13 Battery cabinet front view No 1 with door opened...

Page 18: ...16 Q8 X47 X49 X48 X5 PR X10 Fig 14 Battery cabinet front view No 2 with door closed Fig 15 Battery cabinet front view No 2 with door opened...

Page 19: ...17 Fig 16 Battery cabinet front view No 3 with door closed Fig 17 Battery cabinet front view No 3 with door opened...

Page 20: ...static bypass phase R B version only X15 Terminal of static bypass phase S B version only X16 Terminal of static bypass phase T B version only X17 Terminal of static bypass neutral N B version only 1...

Page 21: ...ng BL of switch Q5 By means of the connectors X36 and X36 the communication loop or ring is closed between two or more equipment connected in parallel by means of the bundle BC These connectors are no...

Page 22: ...s it is used to filter the DC needed for the correct operation of PFC converter and inverter 4 3 3 Batteries This UPS series has a battery set that stores energy during the normal operating mode prese...

Page 23: ...hem The bypass stage is based on six double thyristors in semipack format working as AC switches three of them are for shifting the input over the output and the other three are for shifting the inver...

Page 24: ...consigning a battery discharging current even with existing mains This quality performance will make it possible to do a battery test both in full load and in no load conditions Output three phase rec...

Page 25: ...d in the previous section 4 4 1 Normal operating 4 4 3 Operating with non active inverter The inverter is non active due to alarm conditions like overloads over temperatures etc In this case the recti...

Page 26: ...W N Inp Out COM connections Inp Out Fig 22 Single line diagram connection of parallel system up to 4 units of UPS models COM connections Inp Out R S T N R S T N COM connections U V W N Inp Out COM con...

Page 27: ...ures a quality of AC power supply for the most critical loads The quantity of redundant equipment to be connected has to be studied according to the requirements of the application No matter Parallel...

Page 28: ...attached to the impact indicator located on the packaging Unpacking Check the content before deserting the packaging Unpack the package according to the Unpacking procedure in the supplied document in...

Page 29: ...nce of the floor kg m2 25 cm 25 cm 150 cm 25 cm 25 cm 5 1 4 Location immobilization and considerations 5 1 4 1 Location for single equipment As i e Fig 24 itshows two typical cases depending on the mo...

Page 30: ...ion referred to the installation of a single equipment or parallel system Switchgear or external manual bypass panel boards It is advisable to have an external manual bypass panel board equipped with...

Page 31: ...r power rate are supplied in a separate cabinet Therefore battery protection is arranged as follows In the UPS stated in this document as Q3 Battery fuse holder switch with 3 fuses in models up to 20...

Page 32: ...ipment Connection to three phase mains Connect the power supply cables R S T N to the input terminals X1 X2 X3 and X4 respecting the phase rotation and neutral indicated on the label of the equipment...

Page 33: ...loads to U V W N output terminals X6 X7 X8 and X9 respecting the phase rotation and neutral indicated on the label of the equipment and in this manual If the phase rotation is not respected the equip...

Page 34: ...ng one side to terminals X11 X23 and X12 of UPS and the other one to terminals X47 X49 and X48 of battery module always respecting the stated polarity on the labelling of each element and this manual...

Page 35: ...a communication cable of just 3 wires Physical structure of the RS 232 Pin 2 RXD Serial data reception Pin 3 TXD Serial data transmission Pin 5 GND Ground signal Physical structure of the RS 485 Unli...

Page 36: ...that allows compensating the floating voltage according to the ambient temperature Any wire connected to the terminals X34 X45 and X51 will be entered into the equipment through the cable bushing PR...

Page 37: ...cation BUS To do it connect them in a sequential way two lines of the communication BUS between a unit and its adjacent Together with each UPS of a parallel system it is supplied a 15 wires bundle wit...

Page 38: ...ts to be a guide to clarify the possible doubts on how the communication loop has to be connected To see the physical layout of the COM connectors for each power rate refer to the illustrations of fig...

Page 39: ...n mean while the input voltage is available In those installations without the external manual bypass panel board omit the actions and steps that involve the maneuvering of their switches Fig 33 Proce...

Page 40: ...UPS in the system Turn the input switch Q1a to On position for each UPS in the system Each display of the Control Panel will be turned on automatically Do not close any other switches at this time Re...

Page 41: ...trol panel Turn the output switch Q2 of the UPS On 6 5 COMPLETE SHUTDOWN OF THE UPS Shutdown the loads If the system has outgoing distribution protections switch them Off Shutdown the inverter Please...

Page 42: ...maintenance bypass to normal operation In model with external battery cabinet set fuse holder switch from battery cabinet Q8 to On position In standard units set the input switch Q1a to On position I...

Page 43: ...home from any screen of any submenu we can go back to main screen Screen 0 0 Fig 35 Screen 0 0 Main Screen 7 2 2 CONTROL Level screen menu 1 0 Screens 1 1 and Screen 1 2 It s to start and stop the un...

Page 44: ...about the battery test is given Possible messages EXECUTING The battery test is running SUCCESSFUL The battery test has been successful NOT SUCCESSFUL The battery test has not been successful Screen...

Page 45: ...urrent for three phase equipment per phase for single phase equipment accuracy 0 1A Charging Current Positive and negative accuracy 0 1A Discharging Current Positive and negative accuracy 0 1A Screen...

Page 46: ...he options are the following SEC MODBUS Screen 3 3 Automatic battery test setting The options for the Type to be programmed are the following DISABLED The automatic battery test is disabled WEEKLY The...

Page 47: ...this level an authorized password will be required to modify some advanced parameters If you need to modify advanced setting please check with your dealer to get password Screen 3 5 Rated Value To mod...

Page 48: ...m appears when the input the unit is under main failure condition and the level of battery is lower than 11 5V bat Alarm 4 This alarm appears when the inverter output voltage phase to neutral in any p...

Page 49: ...op UPS Stop 71 Parallel System UPS Stop 72 Emergency Power Off No Output Voltage BYP STOPS 38 Output Short circuit No Output Voltage 39 DSP Internal Error UPS Block All 40 DC BUS Voltage Wrong Rectifi...

Page 50: ...l be blocked after 30 and a blocking alarm 61 will appear Alarm 33 This alarm appears when there is a DSP Internal Error in the inverter module shutting down the inverter immediately There will be 4 m...

Page 51: ...ed Alarm 64 If there is a blocking condition for the inverter and also a blocking condition for the PFC this alarm appears blocking also the UPS Alarm 65 This alarm can be activated due to a connectio...

Page 52: ...as already been chosen as a Fix Master in the system a second error or break in the communications has been detected by the Slaves equipment which will be blocked permanently Rectifier and Inverter ar...

Page 53: ...tween 3 and 7 years if the ambient temperature is between 10 and 20 C To have more information of its status activate the battery test Risk of fire and or explosion exists if a wrong quantity or type...

Page 54: ...rest factor 3 4 to 1 3 2 to 1 2 8 to 1 3 2 to 1 3 to 1 Permissible power factor 0 7 leading to 0 7 lagging Unbalancedoutputvoltage 100 unbalancedload 1 Current limit High overload short circuit RMS vo...

Page 55: ...d THD i 5 0 100 load THD i 1 5 50 load THD i 2 0 10 load THD i 6 0 Current limit High overload PFC limit discharging batteries Power factor 0 99 from 10 load INVERTER Output nominal voltage Single pha...

Page 56: ...UPS CONFIGURATIONS WITH STANDARD BACK UP TIME Quantity of cabinets 1 UPS batteries 1 UPS 1 batteries Maximum dimensions mm Depth x Width x Height UPS UPS B1 770x450x110 875x590x1320 850x900x1900 UPS B...

Page 57: ...uit through which are sent or received signals from a system or subsystems toward others kVA The voltampere is the unit of the apparent power in electrical current In direct current is almost equal to...

Reviews: