2. WARNING (continued) 

2.2. ELECTRIC CONNECTION

The electric connection of the machine must be on a 16A - 230V plug with a differential circuit 

breaker.

Before any intervention on the machine, make sure that every energy supply is cut (air and 
electricity).

GROUND CONNECTOR

All the machines must be connected to the ground when they work to protect the operator from electric 
shocks. Our machines are all equipped with standardized connection plugs.

Electric  connection  must  be  made  by  a  qualified  technician.  It  is  fobidden  to  modify  or  dismantle  the 

machine, especially the electric box.
Repairs must be made by an authorized center or our After-sale Service.

During any intervention on the machine, make sure that the ground is well reconnected.

EXTENSION CORDS

During the use of an extension cord, make sure that it is not crushed or damaged and that it contains a 

ground. Check that the section of the used extension cord is sufficient to support the machine when it is 
working. A too thin extension cord can cause voltage drops or overheating of the machine.

In  case  of  use  of  a  cable  reel,  it  is  imperative  to  unwind  it  entirely,  otherwise,  the  equipment  can  be 

damaged. The section must be proportional to the length of the cord.

2.3. END OF LIFE OF THE PRODUCT

At  its  end-of-life,  the  machine  must  not  be  eliminated  with  the  other  household  waste.  The  
uncontrolled  elimination  of  waste  can  harm  the  environment  or  human  health.  Individuals  are 
invited to contact the distributor which sold them the product or to inquire with their city hall 
to  know  where  and  how  to  get  rid  of  the  product  so  it  can  be  recycled  while  respecting  the 

environment.

Under the regulation of Waste of Electrical and Electronic Equipments (WEEE), we undertake to 
process the used EEEs according to the following provisions: applicable only to products on the 

market since 08/13/05, under the brands EUROPE PROJECTION or VOLUMAIR, products of other 
brands sold by our company (upon presentation of the corresponding invoices), products that 

operate using electrical energy (for example, thermal washers or compressors do not fall into this 

category).

Treatment modality

WEEE returns collected by our clients/distributors at their own expense to our collection points in 

Antony (92) or Rousset sur Arc (13). Upon receipt, the products are sorted by our employees and 
directed to the most appropriate processing channels.

For any further information, please contact our h33 4 42 29 08 96 or conseil@euromair.com.

Summary of Contents for Eole T5 + HV460

Page 1: ...nue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 Eole T5 HV460 User manu...

Page 2: ...y 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SUMMARY 1 USER MANUAL p 3 1 1 Importance of the manual p 3 1 2 Receivers of the manual p 3 2 WARNING p 4 2 1 Safety p 4 2 2 Electric conne...

Page 3: ...by the non compliance of the safety standards and rules This manual must be kept near the machine within reach of the user and held in good condition until the final destruction of the machine In cas...

Page 4: ...a water jet or flammable liquid on the machine Never direct an air jet or product jet on a person or an animal Do not touch warm surfaces of the equipment Always wear adequate body protections glasses...

Page 5: ...hine Take away every not qualified person from the working area of the machine as well as children and animals In case of installation of the machine on scaffolding or a plan above ground level attach...

Page 6: ...t entirely otherwise the equipment can be damaged The section must be proportional to the length of the cord 2 3 END OF LIFE OF THE PRODUCT At its end of life the machine must not be eliminated with t...

Page 7: ...olvent phase 3 2 TECHNICAL CHARACTERISTICS TURBINE Stages 5 Pressure 0 67 bar Air flow rate adjustment yes Power 1700 W Electrical supply 230 V 16 A 50 60 Hz Hose length 7 5 m Dimensions l x w x h 37...

Page 8: ...YOUR MACHINE continued 3 3 IDENTIFICATION OF THE SPRAY GUN COMPONENTS A Nozzle ring B 1 litre bowl C Trigger D Air inlet coupling E Product flow rate adjustment thumbwheel F Atomization kit F1 Diffuse...

Page 9: ...T5 HV460 P9 3 YOUR MACHINE continued 3 4 IDENTIFICATION OF THE TURBINE COMPONENTS H Ventilation filter Bowl filling support I Air outlet coupling J Starting switch K Potentiometer L Thermal circuit b...

Page 10: ...ommendations for use dilution handling etc The product must always be diluted before filling the bowl maximum concentration of pure product 5 Never spray pure products Once the work is finished rinse...

Page 11: ...nd one During utlization use the potentiometer K to increase or decrease the air flow rate into the turbine So that the paint is at the ideal viscosity use the viscosimeter delivered with the turbine...

Page 12: ...POLE The extension pole takes the place of the diffuser head and the jet nozzle Dismantle the ring A Dismantle the jet nozzle F2 Mount the 1 5 mm needle Be sure the joint is well placed Mount the exte...

Page 13: ...a very fluid oil Grease with a consistent grease every thread pitch the front side of the needle nozzle the 2 springs and the centring nut which slides into the back plug Verify and tighten the nut g...

Page 14: ...LE the R 233 73 article of the Labour Code THE DIRECTIVES Machines 2006 42 CE Low voltage 2014 35 UE CEM 2014 30 UE ROHS 2011 65 UE Noise emissions 2005 88 CE AND WITH THE STANDARDS NF EN ISO 12100 NF...

Page 15: ...were totally or partially dismantled Defective equipment will be removed by us Any shipment of equipment by the customer will be at its own expense The guarantee will be subject to the presentation o...

Page 16: ...venue Olivier Perroy 13790 ROUSSET T l 33 0 4 42 29 08 96 Fax 33 0 4 42 53 44 36 SAS au capital de 400 000 RCS Aix en Provence B 394 961 510 NAF 2892 Z Intracom FR 54 394 961 510 User manual Eole T5 H...

Reviews: