Engine Shutdown
Before Engine Shutdown
Let the engine run at high idle (1500 or 1800rpm) for a
minimum of 5 minutes before the shutdown after
normal use. Normal use is defined as minimum 50%
load. After use with less than 50% load, high idle for
approximately 3 minutes is sufficient. This allows
engine temperature equalization and prevents boiling
once stopped and also allows the turbochargers to cool
down. This contributes to long, fault-free service life.
NOTICE!
Do not turn off the main switch within 30
seconds after turning off the ignition. This is in order to
save engine data to the engine control unit.
Stop the Engine
1 Press the stop button until engine speed begins to
fall.
2 Check that the rpm reading drops to 0 and that
engine status changes to “Ready".
Emergency stop
If a fault occurs that prevents you stopping the engine
in the normal way, you can stop it by pressing the
emergency button.
If the engine has been stopped using the emergency
stop button, the button locks in the down position. In
order to be able to restart the engine, the button must
be reset to its original position. To do this, pull the
button upwards until you hear a click.
P0005904
47711740 05-2019 © AB VOLVO PENTA
33