57
Maintenance: Lubrication system
Engine oil. Change
Always observe the recommended oil change interval.
IMPORTANT!
Only use the recommended grade
of oil.
1. Warm up th
e engine (this makes it easier to suck
the oil up from the sump). Let the engine run till op-
eration temperature is reached (temperature gauge
indicate a value between 75 – 100°C (167-212°F)).
2. Stop the engine. Wait ten minutes before draining
the oil.
WARNING!
Hot oil and hot surfaces can cause
burns.
3. Connect the oil bilge pump to the drain pipe and
pump the oil up.
4.
Change the oil filter at each oil change, please re-
fer to “Oil filter. Changing” in this chapter .
5. Fill up with oil to the correct level through the valve
cover cap. Please refer to “Technical Data” for oil
volume.
6.
WARNING!
Working with, or going close to a run-
ning engine is a safety risk. Watch out for rotating
components and hot surfaces.
Start the engine. Let the engine run till operation
temperature is reached (temperature gauge indi-
cate a value between 75 – 100°C (167-212°F).
Check that the low oil pressure warning lamp goes
out.
Check that no leakage occurs by the filter.
IMPORTANT!
The oil level check must be done
on a warm engine. If the oil is cold it will take
very long time for the oil to flow back into the oil
sump.
7. Stop the engine. Wait ten minutes, then check the
oil level. Top up if necessary.
NOTE!
Hand the old oil in to a recycling station.
Summary of Contents for D3-110i-A
Page 1: ...OPERATOR SMANUAL D3 130A A D3 160A A D3 110i A D3 130i A D3 160i A ...
Page 99: ......