Sacrificial Anode
There is an anode in each exhaust riser, see illustra-
tion.
Riser anodes must be checked yearly or once every
100 hours to determine the amount of erosion that has
occurred. If the anode is more than 1/3 eroded,
replace.
1 O-ring
2 Anode – Exhaust elbow; torque to 15–21 ft. lb. (20–
28 Nm) when replacing
Electrical System
Battery Maintenance and
Replacement
22827
DANGER!
Never allow an open flame or electric sparks near the
battery or batteries. Never smoke in proximity to the
batteries. The batteries give off hydrogen gas during
charging which, when mixed with air, can form an
explosive gas. This gas is easily ignited and highly
volatile.
WARNING!
Battery electrolyte is a corrosive acid and should be
handled with care. If you spill or splash electrolyte on
any part of the body, immediately flush the exposed
area with liberal amounts of water and seek medical
attention as soon as possible.