Group 87 Climate Control, Fault Codes
Troubleshooting
MID 146 SID 5 Stepper Motor, Fresh Air and Recirculation
T8008643
T8008561
Component: A34 Climate Control Unit, E32 Climate
unit
General information
The stepper motor opens and closes the shutter for the
fresh air and recirculation. The stepper motor is located
on the front edge of the climate control unit.
Fault code
FMI 4
Abnormally low voltage or short-circuit to lower voltage
Conditions for fault code:
•
If the control unit detects a short-circuit to ground, the
control unit interprets this as an error and a fault code
is stored.
Possible cause:
•
Signal cable to stepper motor Fresh air /Recirculation
short-circuited to lower voltage
•
Signal cable to stepper motor Fresh air /Recirculation
short-circuited to ground
Reaction from the control unit:
•
Fault code is stored
•
Yellow lamp requested
Noticeable external symptoms:
•
Yellow lamp lights up
•
No control of Fresh air / Recirculation SID 5
Appropriate check:
•
See “MID 146 SID 5 Stepper Motor Fresh
Air-recirculation, Check” page 15
14