Group 87 Climate Control, Fault Codes
Troubleshooting
MID 146 SID 19 Stepper Motor, Phase 4
T8008643
T8008572
Component: A34 Climate Control Unit, E32 Climate
Unit
General information
Fault code
FMI 3
Abnormally high voltage or short-circuit to higher voltage
Conditions for fault code:
•
If the control unit detects a short-circuit to voltage,
the control unit interprets this as an error and a fault
code is stored.
Possible cause:
•
The signal cable to phase 4 short circuited to higher
voltage
Reaction from the control unit:
•
Fault code is stored
•
Yellow lamp requested
Noticeable external symptoms:
•
Yellow lamp lights up
•
None of the stepper motors for Fresh air / Recirculation,
Air distribution or Air mixture (SID 5, 6, 9) can be
controlled
Appropriate check:
•
See “MID 146 SID 19 Stepper Motor Phase 4, Check”
page 36
35