Group 87 Climate Control, Fault Codes
Troubleshooting
8730-21-02-12
MID 146 SID 232 5 Volt Supply Sensors, Check
Special tools: 9998534
Other special equipment: J-39200
NOTE
•
Check all relevant connectors. Check for loose
connections, contact resistance and oxidation. For a
more detailed description of fault-tracing wiring
and connectors, see separate service information
under Group 371.
Measurement at the component
connector to the control unit
Note: If one of the values below is incorrect this may also
have caused the component to fail, check the component
if any of the values are incorrect.
Supply cable
1
Conditions:
•
Measurement to the control unit.
•
Refrigerant pressure sensor connector disconnected.
•
Ignition key in on position.
•
Measuring resistance using a J-39200 Digital
Multimeter.
Measurement points
Nominal value
1 - ground
R
≈
0
J-39200
9998534
Supply cable
2
Conditions:
•
Measurement to the control unit.
•
Refrigerant pressure sensor connector disconnected.
•
Ignition key in off position.
•
Measuring voltage using a J-39200 Digital Multimeter.
Measurement points
Nominal value
1 - ground
V
≈
5 V
J-39200
9998534