Group 87 Climate Control, Fault Codes
Troubleshooting
MID 146 SID 6 Stepper Motor, Air Distribution
T8008643
T8008562
Component: A34 Climate Control Unit, E32 Climate
unit
General information
The stepper motor controls the air distribution in the
cab. The stepper motor is located on the left side on the
climate control unit.
Fault code
FMI 4
Abnormally low voltage or short-circuit to lower voltage
Conditions for fault code:
•
If the control unit detects a short-circuit to ground, the
control unit interprets this as an error and an fault code
is stored.
Possible cause:
•
Signal cable to air distribution stepper motor short
circuited to lower voltage
•
Signal cable to air distribution stepper motor short
circuited to ground
Reaction from the control unit:
•
Fault code is stored
•
Yellow lamp requested
Noticeable external symptoms:
•
Yellow lamp lights up
•
No control of Fresh air / Recirculation SID 6
Appropriate check:
•
See “MID 146 SID 6 Stepper Motor Air Distribution,
Check” page 17
16