*941098-00*
941098-00
X
X
Line X-X corresponds to line X-X on exit device instructions
CL
Corresponds to
center line of exit
device on exit
device instructions
11/16” R, 2 places
(omit for BE)
1/2” dia.
2 places
6-1/4”
Outside
face of
lock stile
Inside
face of
lock stile
LHR shown
RHR opposite
5/16” dia.
3”
1/2”
1-7/8”
3/4” dia.
thru one
wall
3/8”
2-1/8”
5/16” dia.
c’sink 1/2” dia x 82 degree
X
X
1.
Prepare door for exit device. See exit
device instructions for locations of
holes, backset (line X-X), and center
lines.
2.
Prepare door for control:
A.
Transfer line X-X from inside (exit
device side) of door to outside
(control side) of door. Use extra
care if edge of door is beveled.
Be sure line X-X is parallel to edge
of door.
B.
Locate and prepare holes as
indicated.
3.
Install rod member (Figure 1):
A.
Slip top rod assembly in door until
bottom of rod is visible in control
cutout.
B.
Slip rod member on top rod
according to handing of door. Keep
rod member visible in cutout and
lower top rod assembly until latch
release is in position on latch release
reinforcement. Slightly tighten socket
set screws in rod member to
maintain this position.
C.
Complete the installation and
adjustment of top and bottom rod
assemblies. See directions for
vertical rod device.
4.
Install cylinder if required (Figs. 2 &3).
Insure cylinder cam is set for required
function and replace if necessary.
5.
Install control and adjust member so
that the bottom surface is against top
surface of control cam. Secure rod
member by tightening socket set
screws.
6.
Apply device and test key, control,
and device action.
1-3/8” dia.
(BE only)
Omit cylinder
for BE function
For cutouts on inside face
of door see instructions in
device carton
Device Application Schedule
8847-F Vertical Rod Exit Device
Control
371-L & 371-L-BE
Installation Instructions
Customer Service
1-877-671-7011
www.allegion.com/us
© Allegion 2014