Motorized Locking Trim
M996L Series
Installation Instructions
M996L
for Rim/Vertical
M996L
for Mortise
Parts Included
Tools Needed
⁵⁄₁₆
" Nut driver
#2 Phillips
1
Retrofit / replace operation if necessary.
(See M996L Series Retrofit, 941389-00)
Change function (Fail Safe or Fail Secure) if necessary.
2
Fig. 2-1
Unit locks when electric
power is applied and
unlocks when power is
removed
FS (fail safe)
factory setting
Unit unlocks when
electric power is applied
and locks when power
is removed
FSE (fail secure)
2.1.
To change function, use the tip of a small screwdriver to CAREFULLY move the switch to the desired position. The
switch is factory set to fail safe (FS). Moving the switch changes the function to fail secure (FSE). After changing FS/FSE
switch position, power cycle the unit two or more times before installation. See Figure 2-1.
FS
FSE
FS
FSE
CAUTION
!
Product is shipped in Fail Safe (FS) configuration. Fail Safe configuration is required by code in some applications (typically fire
stairwells). Consult building codes before converting to Fail Secure (FSE) configuration. See page 8 for FS/FSE function information.
M996 Motorized Module