background image

Page 3 of 8

Check exit device NL drive screw.

4

For mortise device applications see Figure 4-3.
Installation of the NL drive screw sets the exit device for NL (night latch) operation, which is

required for use with the E996L rim/vertical trim.

Fig. 4-1

NL drive

screw

Center case cam

Make sure cup on center case

cam points toward latch bolt

LHR

RHR

NL drive

screw

Center case cam

Make sure cup on center case

cam points toward latch bolt

Fig. 4-2

NOTE

!

Fig. 4-3

For rim/vertical device applications, make sure the NL drive screw is installed in the exit device center 

case cam with the exit device lock slide in the up position. See figure 4-1 for LHR applications and 

Figure 4-2 for RHR applications. (Device is shipped from factory with NL drive screw installed.) 

Rim/Vertical

Mortise

For mortise device applications, NL screw 

located on side of 7500 mortise lock 

remains as shipped for NL operation. As 

shipped position is when NL screw is 

turned out counterclockwise. For any 

questions, contact technical support. 

If the exit device lock slide is not in the up position: Remove NL drive screw 

and use a Phillips head screwdriver to rotate the exit device center case cam 

to move the lock slide into the up position. Then reinstall NL drive screw. 

Make sure latch

bolt is extended

Make sure lock

slide in up

position

Make sure latch

bolt is extended

Make sure lock

slide in up

position

Summary of Contents for M996L Series

Page 1: ...d locks when power is removed FSE fail secure 2 1 To change function use the tip of a small screwdriver to CAREFULLY move the switch to the desired position The switch is factory set to fail safe FS Moving the switch changes the function to fail secure FSE After changing FS FSE switch position power cycle the unit two or more times before installation See Figure 2 1 FS FSE FS FSE CAUTION Product i...

Page 2: ...Page 2 of 8 Connect trim plug to cable plug See Figure 12 1 3 ...

Page 3: ...ce lock slide in the up position See figure 4 1 for LHR applications and Figure 4 2 for RHR applications Device is shipped from factory with NL drive screw installed Rim Vertical Mortise For mortise device applications NL screw located on side of 7500 mortise lock remains as shipped for NL operation As shipped position is when NL screw is turned out counterclockwise For any questions contact techn...

Page 4: ...99 Rim 98 9927 98 9975 3 4 Locate wire access slots 6 Fig 6 1 98 9947 98 99 Rim 98 9927 98 9975 2 3 4 3 4 2 3 4 RHR wire access LHR wire access RHR wire access LHR wire access Note Each center case has 4 slots that can be used for wire access Some slots may be obstructed by optional equipment Drill and deburr 3 8 dia hole here thru exit device side of door for wiring Drill and deburr 3 8 dia hole ...

Page 5: ... Be careful not to pinch cable when sliding mechanism case back against center case 7 3 Route E996L cable through center case slots as shown Figure 7 1 Cable plug should be on door side of center case as shown Figure 7 1 Fig 7 1 RHRShown LHROpposite 98 99 Rim 98 9927 98 9975 98 9947 RHRShown LHROpposite Fig 7 2 Mechanismcase Pushbar guides Baseplate CAUTION Ensure wire will not interfere with movi...

Page 6: ...ce with end cap removed if device is too long for door see Cut Device on device instructions Mounting bracket flush 8 1 Temporarily attach trim and device to door with 4 screws Figure 8 1 8 2 Slide mounting bracket in end of mechanism case and level device then mark two mounting holes on door through bracket holes Figure 8 2 8 3 Mark and prepare two holes for mounting bracket screws Figure 8 3 8 4...

Page 7: ...1 Connect trim plug and cable plug Figure 12 1 12 2 Route wires into corner of the cutout near post Push the wires down into the door to ensure they do not contact the slider Figure 12 1 Note For 98 9947 device hold trim in door and lift center case away from the door surface while rods and trim remain in place Route wiring as shown in Figure 12 2 Verify that the wires do not get wrapped around or...

Page 8: ...m with power disengaged check to ensure that the key override feature night latch functions properly Inserting and turning key will temporarily unlock door while trim lever remains rigid Door locks when key is removed Troubleshooting 16 With the trim plugged into cable the electronic control can be verified using indicators located on the backside of the trim This is only possible when trim is not...