background image

Page 7 of 8

Attach center case to door.

10

10.1.

Support hinge side of device in mounting bracket.

10.2.

 If trim has been temporarily installed, remove 4 screws in center case and remove trim.

10.3.

Pull center case away from door and route E996L cable plug through wire access hole in

door (Figure 10-1).

10.4.

 For 98/99 Rim, 98/9927, and 98/9975 secure center case to door using two support

screws (Figure 10-1) or by some other temporary means (use clamps, have a helper hold the

device, etc.).

Fig. 10-1

Two support screws

Two support screws

Cable plug

Cable plug

Install trim on door.

12

12.1.

 Connect trim plug and cable plug (Figure 12-1).

12.2.

 Route wires into corner of the cutout near post. Push the wires down into the door to

ensure they do not contact the slider (Figure 12-1).

Note:

 For 98/9947 device, hold trim in door and lift center case away from the door surface while

rods and trim remain in place. Route wiring as shown in Figure 12-2. Verify that the wires do

not get wrapped around or pinched in rods or slider, then align center case and attach rods.

12.3.

 Attach trim to door using four screws through device center case (Figure 12-3).

12.4.

 Install center case cover (see device instructions if necessary).

Fig. 12-1

Plugs

For vertical or mortise devices, install vertical rods or mortise lock in door.

11

RHR

LHR

Fig. 12-3

Trim

Fig. 12-2

Rods and slider

(no interference)

Summary of Contents for M996L Series

Page 1: ...d locks when power is removed FSE fail secure 2 1 To change function use the tip of a small screwdriver to CAREFULLY move the switch to the desired position The switch is factory set to fail safe FS Moving the switch changes the function to fail secure FSE After changing FS FSE switch position power cycle the unit two or more times before installation See Figure 2 1 FS FSE FS FSE CAUTION Product i...

Page 2: ...Page 2 of 8 Connect trim plug to cable plug See Figure 12 1 3 ...

Page 3: ...ce lock slide in the up position See figure 4 1 for LHR applications and Figure 4 2 for RHR applications Device is shipped from factory with NL drive screw installed Rim Vertical Mortise For mortise device applications NL screw located on side of 7500 mortise lock remains as shipped for NL operation As shipped position is when NL screw is turned out counterclockwise For any questions contact techn...

Page 4: ...99 Rim 98 9927 98 9975 3 4 Locate wire access slots 6 Fig 6 1 98 9947 98 99 Rim 98 9927 98 9975 2 3 4 3 4 2 3 4 RHR wire access LHR wire access RHR wire access LHR wire access Note Each center case has 4 slots that can be used for wire access Some slots may be obstructed by optional equipment Drill and deburr 3 8 dia hole here thru exit device side of door for wiring Drill and deburr 3 8 dia hole ...

Page 5: ... Be careful not to pinch cable when sliding mechanism case back against center case 7 3 Route E996L cable through center case slots as shown Figure 7 1 Cable plug should be on door side of center case as shown Figure 7 1 Fig 7 1 RHRShown LHROpposite 98 99 Rim 98 9927 98 9975 98 9947 RHRShown LHROpposite Fig 7 2 Mechanismcase Pushbar guides Baseplate CAUTION Ensure wire will not interfere with movi...

Page 6: ...ce with end cap removed if device is too long for door see Cut Device on device instructions Mounting bracket flush 8 1 Temporarily attach trim and device to door with 4 screws Figure 8 1 8 2 Slide mounting bracket in end of mechanism case and level device then mark two mounting holes on door through bracket holes Figure 8 2 8 3 Mark and prepare two holes for mounting bracket screws Figure 8 3 8 4...

Page 7: ...1 Connect trim plug and cable plug Figure 12 1 12 2 Route wires into corner of the cutout near post Push the wires down into the door to ensure they do not contact the slider Figure 12 1 Note For 98 9947 device hold trim in door and lift center case away from the door surface while rods and trim remain in place Route wiring as shown in Figure 12 2 Verify that the wires do not get wrapped around or...

Page 8: ...m with power disengaged check to ensure that the key override feature night latch functions properly Inserting and turning key will temporarily unlock door while trim lever remains rigid Door locks when key is removed Troubleshooting 16 With the trim plugged into cable the electronic control can be verified using indicators located on the backside of the trim This is only possible when trim is not...

Reviews: