Page 7 of 8
Attach center case to door.
10
10.1.
Support hinge side of device in mounting bracket.
10.2.
If trim has been temporarily installed, remove 4 screws in center case and remove trim.
10.3.
Pull center case away from door and route E996L cable plug through wire access hole in
door (Figure 10-1).
10.4.
For 98/99 Rim, 98/9927, and 98/9975 secure center case to door using two support
screws (Figure 10-1) or by some other temporary means (use clamps, have a helper hold the
device, etc.).
Fig. 10-1
Two support screws
Two support screws
Cable plug
Cable plug
Install trim on door.
12
12.1.
Connect trim plug and cable plug (Figure 12-1).
12.2.
Route wires into corner of the cutout near post. Push the wires down into the door to
ensure they do not contact the slider (Figure 12-1).
Note:
For 98/9947 device, hold trim in door and lift center case away from the door surface while
rods and trim remain in place. Route wiring as shown in Figure 12-2. Verify that the wires do
not get wrapped around or pinched in rods or slider, then align center case and attach rods.
12.3.
Attach trim to door using four screws through device center case (Figure 12-3).
12.4.
Install center case cover (see device instructions if necessary).
Fig. 12-1
Plugs
For vertical or mortise devices, install vertical rods or mortise lock in door.
11
RHR
LHR
Fig. 12-3
Trim
Fig. 12-2
Rods and slider