3.
Configuration Description
3.1
IP address and device ID
3.1.1
Preparation
In order to establish communication in the VIPCOS system, it is necessary to assign an individual IP
address in the same IP address range and a device ID between
1000
and
9999
to each device. First,
you should adjust the V640's IP address. By default, the IP address is
192.168.100.10 / 255.255.255.0.
Next, the call station needs an individual ID in order to be able to make an assignment for direct and
SIP calls.
In our example, we will adjust the IP and ID of
two
V640 desktop call stations and thus create the first
requirement for communication in VIPCOS System.
First create an environment as described in
chapter 1.2
and get access to the web interface of first
V640:
192.168.100.64 /
255.255.255.0
ID: 1640
192.168.100.65 /
255.255.255.0
ID: 1650
192.168.100.250 /
255.255.255.0
Cat.5e