Series S34 Instruction Manual
Appendix D Quick Start-Up Guide
M-000-00030
D-1
Appendix D Quick Start-Up Guide
1.
Turn on power to the handheld unit
by pressing the “POWER” button
.
2.
Press “ENTER”
. A screen with
“Enter Password”
will be displayed.
a.
Enter the “User Password” of 1234
.
3.
Using the left/
right arrow, navigate to the “Fluid”
menu.
a.
Press the up/
down arrow to access the “Flowing Fluid”
sub-menu.
b.
Press “Enter” and select the type of liquid
to be measured.
i.
Use the up/down arrow to scroll through the list of fluids.
ii.
Note:
If the liquid used in your system is not represented in this list use the
“Other Liquid” category and input the necessary parameters
.
c.
Press “Enter”
after selecting the type of liquid.
i.
This will save the current configuration.
d.
Press the up/
down arrow to return to the “Fluid”
menu.
4.
Using the right arrow, navigate to the “Units”
menu.
a.
Using the up/down arrow, define the required units.
5.
Using the right arrow, navigate to the “Calibration”
menu.
a.
Enter the “Pipe OD” and the “Wall Thickness”
.
i.
“Pipe ID” will be calculated
.
b.
Enter “Pipe Material” and “Liner Material”
.
c.
Enter the “Transducer Type”
.
i.
2 MHz
1.
Typical p
ipe sizes: ½” to 6”
ii.
1 MHz
1.
Typical p
ipe sizes: 2” to 20”
iii.
½ MHz
1.
Typical p
ipe sizes: 12” to 200”
d.
Enter the “Trans Traverse”
.
i.
W method
–
Typically used with pipe sizes ranging from
½” to
4
”
ii.
V method
–
Typically used with pipe sizes ranging from
4” to 12”
iii.
Z method
–
Typically used with pipe sizes ranging from
12” and up
e.
Enter “Spacing Temp (°F)”.
i.
Note: this is the temperature of the liquid at the time of transducer installation.
f.
Enter “
Fluid Temp. 1
”
.
i.
Select:
1.
“Use RTD”
2.
“Don’t Use RTD”
a.
Enter temperature of liquid being measured
Summary of Contents for SonoPro S34 Series
Page 34: ...Series S34 Instruction Manual Chapter 3 Operation 3 5 M 000 00030 Output Menu...
Page 69: ...Series S34 Instruction Manual Appendix A Specifications A 2 M 000 00030...
Page 73: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 2 M 000 00030 Pipe Chart...
Page 74: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 3 M 000 00030...
Page 75: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 4 M 000 00030...
Page 76: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 5 M 000 00030...
Page 77: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 6 M 000 00030...
Page 78: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 7 M 000 00030...
Page 79: ...Series S34 Instruction Manual Appendix C Sound Speed and Pipe Data C 8 M 000 00030...