background image

V-400x Series Digital Clock

 

 

Operating and Installation Instructions

 

 
 

 Time and Date Setting

 

 

The V-400x series digital clocks can be configured to automatically adjust for daylight savings changes, 
however if the unit is run in Standalone mode of operation (i.e. unsynchronised), you may occasionally

 

 

 

 

 

 
 

need to manually adjust the time.Please refer to the diagram below for further information.

 

 

 

 

 

 

 
 

Function ‘Time Setting Mode’. Press ‘Up‘ to enter ‘Time Setting Mode’ and set the seconds count.

 

 

 

 

 

 

 

 

Seconds Setting Mode. Press ‘+’ to increment seconds, ‘‐’ to set to zero. Press ‘Up’ to set minutes count.

 

 

Minutes Setting Mode. Press ‘+’ or ‘‐’ to increment or decrement minutes. Press ‘Up’ to set the hours 
count. Complete time setting process detailed in table below.

 

 

Fu Ti

 

Time and Date settings

 

 

 

Function

 

Display Type

 

 

 

Description

 

'Up' button function

 

 

 

hh:mm:ss

 

 

 

 

hh:mm (4200) (4010)

 

 

 

Second

 

36

 

12

 

47

36

 

Set second (minus button zeros seconds).

 

Select minutes

 

Minute

 

12 

47

 

12

 

47

36

 

Set minute.

 

Select hours

 

Hour

 

12

47

 

12

47 36

 

Set hour.

 

Select year

 

Year

 

20 14

 

20

 

14

 

Set year.

 

Select month

 

Month

 

26 

06

 

26

06

14

 

Set month.

 

Select day of month

 

Day of Month

 

26

06

 

26

06 15

 

Set day of month.

 

Select Leap Second

 

Leap Second

 

LS 

No

 

LS 

No

 

Enable leap second ‐ 59, No or 61. (Please leave at

 

Exit to Time Display

 

 

 

 

 

0 unless a leap second is scheduled)

 

 

 

 

 

 

 

 

 

 

6

 

Issue 2.0

 

Summary of Contents for V-400x Series

Page 1: ... 4 3Function Programming Page 5 4Time and Date Setting Page 6 5Location Setup Page 7 6Synchronisation Setup Page 9 7Network Setup Page 12 8aDisplay Setup 4200x and 4010x series Page 13 8bCalendar Setup 4500x and 4600x series Page 14 9Stopwatch Setup Page 15 10External Interface Setup Page 16 11System Setup Page 16 12Display Status Page 16 ...

Page 2: ... 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation The equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a part...

Page 3: ... All of the digital clocks also have the ability to operate as a multi range programmable stopwatch using supplied infrared remote control or for 400N and 400A units only using an external stopwatch control panel or user supplied voltage free contact closure or switch Simple Operation All V 400x digital clocks are supplied with an infrared remote control to allow for easy setup and control of stop...

Page 4: ...ly accessible All installation work should be performed in accordance with current Building Regulations and the Seventeenth Edition of the IEE Wiring Regulations or equivalent local standard The power supply is fitted with an internal fuse In case of fault the fuse should only be replaced with a fuse of the same rating by a suitably qualified engineer after disconnection from the mains power suppl...

Page 5: ...Function Location Setting Mode See page 5 1 Press Up to enter Location Setting Mode or press to move to next setting Function Synchronisation Setting Mode See page 6 1 Press Up to enter Synchronisation Setting Mode or press to move to next setting The other function menu options are detailed in the table below Function Menu Options Function Section Ti Time and Date Setup Manually set time and date...

Page 6: ...ero Press Up to set minutes count Minutes Setting Mode Press or to increment or decrement minutes Press Up to set the hours count Complete time setting process detailed in table below Fu Ti Time and Date settings Function Display Type Description Up button function hh mm ss hh mm 4200 4010 Second 36 12 4736 Set second minus button zeros seconds Select minutes Minute 12 47 12 4736 Set minute Select...

Page 7: ...ola 1 No 03 CET CEST MEZ MESZ Brussels Frankfurt 1 Yes 04 UTC 2 BRAVO SAST Jo burg Pretoria S Africa 2 No 05 EET EEST Greece Athens Ukraine Kiev 2 Yes 06 IST IDT Israel Tel Aviv 2 Yes 07 MSK 1 Russia Kaliningrad 3 No 08 UTC 3 CHARLIE AST Iraq Baghdad S Arabia Riyadh 3 No 09 MSK Russia Moscow 4 No 10 IRST IRDT Iran Tehran 3 Yes 11 UTC 4 DELTA GST UAE Dubai Abu Dhabi 4 No 12 AZT AZST Azerbaijan Baku...

Page 8: ...Buenos Aires 3 No 63 BRT BRST Brazil Brasilia Sao Paulo 3 Yes 64 WGT WGST Greenland West Nuuk 3 Yes 65 PMST PMDT US Pierre Miquelon 3 Yes 66 UYT UYST Uruguay Montevideo 3 Yes 67 UTC 2 5 2 1 2 No 68 UTC 2 OSCAR 2 No 69 UTC 1 NOVEMBER CVT Cape Verdi Praia 1 No 70 AZOT AZOST Portugal Azores 1 Yes 71 EGT EGST Greenland East Ittoqqortoormiit 1 Yes 72 Morocco Rabat Casablanca 0 Yes 73 WT WST Western Sah...

Page 9: ...y customers DHCP server User setting of NTP display server addresses dh No dh No Static assignment of IP Subnet and Gateway addresses Select IP Byte 1 by user User setting of NTP server addresses IP Byte 1 I 010 I 010 IP Address setting 1st Byte Octet Select IP Byte 2 Range 0 254 IP Byte 2 I 001 I 001 IP Address setting 2nd Byte Octet Select IP Byte 3 Range 0 255 IP Byte 3 I 000 I 000 IP Address s...

Page 10: ...e code from existing 5200 4860 or 482D series master clock Y Y Y Zo 1 F w482 time code zone that unit will use for synchronisation DCF DCF77 Radio time code synchronisation Y Y requires 484 03 radio receiver MSF MSF60 Radio time code synchronisation Y Y requires 484 02 radio receiver MOBA MOBALinetime code from ETC or DTS series master clock Y Y Y Of 720 Offset in minutes of input MOBALine time si...

Page 11: ...d the Up arrow should be pressed again to return to the time display If clock is to DHCP or Static modes the 4 bytes of the first NTP time server address can be programmed in same manner as detailed for the IP address in Section 7 6 Press buttons until each of the 4 address bytes is displayed 7 Press Up to return to time display GPS and GLONASS Synchronisation The 400A and 400N series digital cloc...

Page 12: ...utton until required w482 time zone number is selected not required for 48x0 7 Press Up button to select either 48x0 or w482 synchronisation Clock configuration 1 Press Menu or Up button to access clock settings menu 2 Press button until Fu Sy is displayed 3 Press Up button to access Synchronisation menu 4 Press button until either DCF or MSF is displayed 5 Press Up button to select DCF or MSF syn...

Page 13: ... time date and continuous date in a number of different display formats as detailed in the table below Fu Di Display Setup Function Display Type Up button Description function hh mm hh mm ss 4200 4010 Display Style ti dsti Standard time display Exit to Time display gb ds gb Alternating time and date in ddmmyy 4010 or ddmm Display hold time 4200 format us ds us Alternating time and date in mmddyy 4...

Page 14: ...ge table below Calendar 2 Mode Language Calendar 2 Mode M2 xx As mode settings for Calendar 1 above Calendar 2 Lang Calendar 2 C2 xx Calendar 2 Language as per language table below Calendar 3 Mode Language Calendar 3 Mode M3 xx As mode settings for Calendar 1 above Calendar 3 Lang Calendar 3 C3 xx Calendar 3 Language as per language table below Exit to Time Language display Please refer to the dia...

Page 15: ...ect hold mode zero SA 04 SA 04 Down from pre programmed start time automatically Select hold mode restart countdown Hold Mode SB 01 SB 01 Single start stop start stop count action No hold Select display function resolution SB 02 SB 02 Start stop start stop count action Hold action displays Select display accumulated split time resolution SB 03 SB 03 Start stop start stop count action Hold action d...

Page 16: ... Exit to time provide synchronisation to a maximum 5 400A units display See Local Master documentation for further details 11 System setup The system setup menu contains general setup options for the V 400x series digital clock displays as follows Fu St System Setup Function Display Type Description Up button function hh mm hh mm ss 4200 4010 Display Brightness BrA BrA Display brightness can be au...

Reviews: