70
11D
11D
note: don't remove connected wires
Wiring for 2 speeds with 2 poles switch: MAX/MIN
1
2 POLES SWITCH (DPST)
2
PRODUCT TERMINALS
3
CHANGEOVER SWITCH
1
L
N
2
3
MAX
MIN
N1
L2
5
3
4
6
11E
11E
note: don't remove connected wires
Wiring for 2 speeds with 2 poles switch: MAX/MID
1
2 POLES SWITCH (DPST)
2
PRODUCT TERMINALS
3
CHANGEOVER SWITCH
1
L
N
2
3
MAX
MID
N1
L2
5
3
4
6
Summary of Contents for CA MD W