ENGLISH
Electrical connections HRI-E TWO F
Installer panel (fig.11)
Interface signals (fig.12)
Interface signals without ON/OFF remote control (fig.13)
Power supply (fig.14)
Use
HRI-E TWO:
the appliance is wired to a standard wall-
mounted control box, incorporating a speed selector. .
HRI-E TWO F:
the appliance is wired to a special
dedicated control panel of which the functions are
described further on
This model can be used in combination with a Vortice
preheater, which must be fitted and set up by the
installer.
The minimum distance of the preheater from the
appliance is 500 mm.
Level one thermostat cut-in threshold: 45 °C.
Level two thermostat cut-in threshold: 85 °C.
User panel functions
General
(fig.15)
A = “UP” button: list up
B = “DOWN” button: list down
C = SET button: acquire data
D = ESC button: exit
E = display
This model comes with a panel which offers the user
control of the parameters:
- on/off
- current time/day
- operating speed
- required room temperature
- selection of bypass function
The function of the ESC button, unless otherwise stated,
is always that of quitting without saving data.
11
1
11
1
2
3
1 brown / +12V dc
2 blue / signal
3 black / GND
12
1
12
13
1
13
14
1
14
esc
set
15
1
15
By-Pass
/ °C
1
2
3
4
5
6
7
P1
P2
Prg
A
B
C
D
E
FILT
HA
21