18
power supply. A protec-tive fuse must also be installed, adequately sized and of a delayed type for starting motors.
Attaching or hanging any object from the ceiling fan's blades for any reason, is forbidden. This is because such actions
could result in the machine being out of balance, with a resulting anomalous distribution of loads and consequences
such as the machine falling.
WARNING: SPECIFICALLY INSERT A SINGLE POWER SUPPLY LINE, FITTING A CLASS A TRIP SWITCH IN THE
LINE, IN ADDITION TO A PROTECTIVE CIRCUIT BREAKER IS OBLIGATORY. INSTALLING THE CEILING FAN
NEAR HIGH VOLTAGE LINES (GREATER THAN 1000 V AL-TERNATING CURRENT OR 1500 V DIRECT
CURRENT) IS EXPRESSLY FORBIDDEN.
6.1
Preliminary operations
Before starting the ceiling fan, check that:
All electrical connections have been formed according to the instructions givenin this manual;
1)
The ceiling fan is free and clean;
2)
6.2
Starting for the first time
Once assembly, installation and the electrical connection for the machine have been completed, power
the machine and wait for about 30 seconds to allow it to complete a self-diagnosis of its default parameters,
and then start rotating. Subsequently, check that:
There is no imbalance in the installation due to incorrect assembly of components, or la-tent defects in the same.
a.
There are no metal noises or sounds coming from the machine itself
b.
The motor's diagnosis LED flashes every 2 seconds.
c.
Rotation is clockwise, when looked at from below the ceiling fan.
d.
6.3
Emergengy stoppage
In an emergency, switch off the power supply to the machine via the circuit breaker or the main power supply set up.
Warning! Do not touch the machine for a period of 5 minutes after switching off the power, because the outside tem-
perature of the machine may exceed 70°C.
6.4
Starting
The machine starts automatically as soon as electricity is supplied to it, after a delay of about 30 seconds to allow au-
tomatic setting of the operating parameters. To start the ceiling fan correctly, see the installation manual enclosed
with this manual. The fan speed is adjustable by an optional potentiometer. The maximum fan speed is indicated in
the 8.1 Technical Data Table.
6 OPERATION
Summary of Contents for Nordik HVSL Super Blade 110 V Series
Page 1: ...NORDIK HVLS SUPER BLADE E SUPER BLADE 110 V Instruction booklet COD 5 571 084 939 23 07 2021 ...
Page 25: ...25 INVERTER MOTOR ELECTRONICS QUICK CONNECTORS ...
Page 28: ...28 Destratification Fan assembly ...
Page 56: ...56 Attachment 2 Electric connection ...
Page 67: ...67 Multi wire diagram for system wiring SINGLE PHASE 85 264V 50 60 Hz ...
Page 78: ......
Page 79: ......