26
85290 - 07.2021 - V5
INSTRUCTION MANUAL VOSS.FARMING EASYCUT PRO
9.2 SHARPENING BLADES
CAUTION
The sharpening of the blades may only be carried out by specialist dealers using
specialist equipment. Do not sharpen the blades yourself.
10 TROUBLESHOOTING
NOTICE
►
Do not make any improper changes or modifications to the unit.
►
Never open the housing. Contact the service department for repairs.
If the device malfunctions or is found to be otherwise defective, even after following
the suggested solutions below, contact the service department. The contact details can
be found in chapter 14.
Motor
Fault/Problem
Cause
Solution
Motor does not run
1. No current
2.
Cable, Switch or
motor defective
1.
Check the socket and fuse used
and have them checked/replaced
by qualified personnel if necessary.
2. Contact the service department.
Motor gets hot
1.
Air filter clogged
2. Blade tension is too
high
3.
Blade and/or head
are dry
4. Defective ball
bearing
1.
Clean or replace the air filter.
2. Reduce the tension of the blades
with the tensioning nut. If this
solves the problem and the
machine stops cutting, the blades
must be sharpened.
3.
Lubricate the blades/ clipper head.
4. Contact the service department.
Motor vibrates
1. Rotor runs out of
round
2.
Bearings are worn
out
3.
Fan wheel broken
Contact the service department.
Motor is very loud
Bearings seized up
Contact the service department.