To install the new motor, proceed as follows:
1. Feed the cable through the notched arm and insert the wire end of the motor into the
notched arm.
2. Press the notched arm into position inserting the other end of the motor into the other
notched arm and secure in place using the four (4) bolt/locking washer/nut sets.
3. Plug in the motor plug into the Power Distribution Unit.
6.8.1 Replace the Conveyor Belt
To replace the conveyor belt, proceed as follows:
1. Access the conveyor rollers by opening the access panel (either front or back).
2. Thread a new belt through the scanner rollers taking care when feeding it through the rollers
in the base.
3. Match the ends of the conveyor belt at the seam and re-thread the seam using the nylon
locking strip.
4. Tighten the conveyor assembly at the conveyor idler-end, using the tension spring.
5. Replace the conveyor belt covers and the shroud.
6. Test the conveyor belt movement using the conveyor buttons on the Operator screen.
Use a weight (approximately 50K or 25 lbs) to ensure the belt does not slip on the rollers.
6.8.2 Replace and Setup the Motor Drive
Before continuing, perform the following calculation:
Summary of Contents for XR3D-6
Page 2: ...XR3D 6 Maintenance Troubleshooting ii EM XR3D 6 001 EN D 2011 VOTI Inc...
Page 6: ......
Page 20: ...XR3D 6 Maintenance Troubleshooting 2 8 EM XR3D 6 001 EN D 2011 VOTI Inc...
Page 32: ...XR3D 6 Maintenance Troubleshooting 3 12 EM XR3D 6 001 EN D 2011 VOTI Inc...
Page 48: ...XR3D 6 Maintenance Troubleshooting 3 28 EM XR3D 6 001 EN D 2011 VOTI Inc...
Page 52: ...XR3D 6 Maintenance Troubleshooting 4 4 EM XR3D 6 001 EN D 2011 VOTI Inc...