background image

‐ 

7

 ‐ 

 

      

 

 

Safety

 

Regulations

 

and

 

Appropriate

 

Application

 

 
 

The

 

LCD

 

Thermometer

 

/

 

Clock

 

S

 

had

 

been

 

designed

 

according

 

to

 

the

 

valid

 

safety

 

regulations.

 

 

Appropriate

 

application

 

is

 

restricted

 

to:

 

1.

 

Operation

 

with

 

12

 

V

 

/

 

24

 

V

 

direct

 

voltage

 

(board

 

mains

 

supply

 

nominal

 

voltage)

 

in

 

fixed

 

installed

 

systems.

 

 

2.

 

Technically

 

faultless

 

condition.

 

3.

 

Installation

 

in

 

a

 

well

ventilated

 

room,

 

protected

 

from

 

rain,

 

humidity,

 

dust,

 

aggressive

 

battery

 

gas,

 

as

 

well

 

as

 

in

 

an

 

environment

 

being

 

free

 

from

 

condensation

 

water.

 

4.

 

With

 

a

 

rear

 

insulating

 

cover

 

of

 

the

 

display

 

unit.

 

 

 

Never

 

use

 

the

 

unit

 

at

 

locations

 

where

 

the

 

risk

 

of

 

gas

 

or

 

dust

 

explosion

 

exists!

 

 

Open

air

 

operation

 

of

 

the

 

unit

 

is

 

not

 

allowed.

 

 

Cables

 

are

 

always

 

to

 

be

 

laid

 

in

 

such

 

a

 

way

 

that

 

damage

 

is

 

excluded.

 

Observe

 

to

 

fasten

 

them

 

tightly.

 

 

Never

 

lay

 

12

 

V

 

(24

 

V)

 

cables

 

and

 

230

 

V

 

mains

 

supply

 

cables

 

into

 

the

 

same

 

cable

 

conduit

 

(empty

 

conduit).

 

 

Check

 

live

 

cables

 

or

 

leads

 

periodically

 

for

 

insulation

 

faults,

 

points

 

of

 

break

 

or

 

loosened

 

connections.

 

Occurring

 

defects

 

must

 

be

 

remedied

 

immediately.

  

 

The

 

unit

 

is

 

to

 

be

 

disconnected

 

from

 

any

 

connection

 

prior

 

to

 

execution

 

of

 

electrically

 

welding

 

or

 

work

 

on

 

the

 

electric

 

system.

 

 

If

 

the

 

non

commercial

 

end

user

 

is

 

not

 

able

 

to

 

recognize

 

the

 

characteristic

 

values

 

being

 

valid

 

for

 

a

 

unit

 

or

 

the

 

regulations

 

to

 

be

 

observed,

 

a

 

specialist

 

is

 

always

 

to

 

be

 

consulted.

 

 

The

 

user/buyer

 

is

 

obliged

 

to

 

observe

 

any

 

construction

 

and

 

safety

 

regulations.

 

 

The

 

unit

 

is

 

not

 

equipped

 

with

 

parts,

 

which

 

can

 

be

 

replaced

 

by

 

the

 

user.

  

 

Non

observance

 

may

 

result

 

in

 

injury

 

or

 

material

 

damage.

 

 

Never

 

use

 

solvents

 

or

 

aggressive

 

household

 

cleaners

 

for

 

cleaning

 

of

 

the

 

display!

 

 

The

 

warranty

 

period

 

is

 

24

 

months

 

from

 

the

 

purchase

 

date

 

(against

 

presentation

 

of

 

the

 

sales

 

slip

 

or

 

invoice).

 

 

The

 

warranty

 

will

 

be

 

void

 

in

 

case

 

of

 

any

 

inappropriate

 

utilisation

 

of

 

the

 

unit,

 

if

 

it

 

is

 

used

 

beyond

 

the

 

technical

 

specification,

 

in

 

case

 

of

 

improper

 

operation

 

or

 

external

 

intervention.

 

We

 

do

 

not

 

assume

 

any

 

liability

 

for

 

any

 

damage

 

resulting

 

hereof.

 

The

 

liability

 

exclusion

 

is

 

extended

 

to

 

any

 

service

 

being

 

executed

 

by

 

third,

 

which

 

has

 

not

 

been

 

ordered

 

by

 

us

 

in

 

writing.

 

Service

 

is

 

to

 

be

 

effected

 

exclusively

 

by

 

VOTRONIC

 

D

36341Lauterbach/Germany.

 

 

 

 

Summary of Contents for 1253

Page 1: ...f its illumination Appearance and dimensions of the display are perfectly adapted to the VOTRONIC modular system The VOTRONIC modular system includes tank display units fresh and sewage water as well as feces the LCD series solar computer battery computer ammeter and voltmeter as well as switch and fuse panels Installation and Connection Choose a well visible and easily accessible location in the ...

Page 2: ...matic activation of the clock and of its illumination Connect the supplied resistor 1 kΩ between the terminals Sens and Sens 2 and connect a control voltage to the terminal Sens 2 In this case connection and use of a second temperature sensor is not possible The use of the second input as control input for the illumination must be set in the menu The illumination of the display is still active for...

Page 3: ...he display brightness is effected in switched on condition and by pressing and holding the keys 1 and 2 for more than 3 seconds until the desired brightness is achieved Displays clock and thermometer The displays of clock and thermometer can be scrolled forwards and backwards by means of the keys 1 and 2 as shown below Time The current time is displayed The colon between hours and minutes is flash...

Page 4: ...1 and 2 Acknowledge using key 3 The display changes to the year Set the year using key 1 and 2 Acknowledge using key 3 Setting of the second measuring input If the automatic activation of the illumination shall be used set the second measuring input to SENS no Thus the temperature measurement of the 2nd input is deactivated The menu item for the setting of the automatic illumination is only displa...

Page 5: ...ctor is at discretion A marking in the display near the antenna symbol indicates the condition of the DCF reception Flashing marking The module receives the time the synchronisation is in progress Lighting symbol The synchronisation of the internal clock with the DCF time was successful After a restart it might take some minutes until the synchronisation starts The synchronisation itself might als...

Page 6: ...tart up is to be executed as described above Display Err a Short circuit at one of the temperature sensors b Resistor between the terminals Sens 2 and Sens had not been removed and the input shall be used for temperature measurement or it shall not be used at all Remove the resistor Display a Temperature sensor had not been connected or cables are interrupted No DCF reception a DCF module not exis...

Page 7: ...efects must be remedied immediately The unit is to be disconnected from any connection prior to execution of electrically welding or work on the electric system If the non commercial end user is not able to recognize the characteristic values being valid for a unit or the regulations to be observed a specialist is always to be consulted The user buyer is obliged to observe any construction and saf...

Page 8: ...e Sensor 825 Order No 2001 DCF Module Order No 2062 Disposal of the product in the normal household waste is not allowed The product conforms to RoHS Thus it complies with the directives for Reduction of Hazardous Substances in Electrical and Electronic Equipment Declaration of Conformity According to the stipulations of the regulations 2006 95 EG 2004 108 EG 95 54 EG this product corresponds to t...